2.4 Setting Commands
p6 Interval: Minutes (MM) (00 to 59)
p7 Timer action
Single
Repeat
Match Time Timer That Synchronizes Once a Month
Syntax
SMatchTimer,p1,p2,p3,p4,p5,p6
p1 Match time timer number (1 to 12)
p2 Type (Month)
p3 Start time: Day (1 to 28)
P4 Interval: Hours (HH) (00 to 23)
p5 Interval: Minutes (MM) (00 to 59)
p6 Timer action
Single
Repeat
Match Time Timer That Synchronizes Once a Week
Syntax
SMatchTimer,p1,p2,p3,p4,p5,p6
p1 Match time timer number (1 to 12)
p2 Type (Week)
p3 Start time: Day of week
Sun
Mon
Tue
Wed
Thu
Fri
Sat
P4 Interval: Hours (HH) (00 to 23)
p5 Interval: Minutes (MM) (00 to 59)
p6 Timer action
Single
Repeat
Match Time Timer That Synchronizes Once a Day
Syntax
SMatchTimer,p1,p2,p3,p4,p5
p1 Match time timer number (1 to 12)
p2 Type (Day)
p3 Interval: Hours (HH) (00 to 23)
P4 Interval: Minutes (MM) (00 to 59)
p5 Timer action
Single
Repeat
Query
SMatchTimer[,p1]?
Example Sets match time timer number 2 to a timer that
operates on 21 hours 30 minutes on April 17
every year.
SMatchTimer,2,Year,Apr,17,21,30,Re
peat
Description
You cannot use this command to configure settings
while recording is in progress.
You cannot use this command to configure settings
while computation is in progress.
If p2=Off, you cannot set p3 or subsequent
parameters.
2-42
Single shot
Repeat
Single shot
Repeat
Single shot
Repeat
Single shot
Repeat
SEventAct
Event Action
Sets an event action.
Syntax
SEventAct,p1,p2,p3,p4,p5,p6,p7
SEventAct,p1,p2,p3,p4,p5,p6,p7,p8
SEventAct,p1,p2,p3,p4,p5,p6,p7,p8
,p9
SEventAct,p1,p2,p3,p4,p5,p6,p7,p8,
p9,p10
SEventAct,p1,p2,p3,p4,p5,p6,p7,p8,
p9,p10,p11
p1 Event action number (1 to 50)
p2 Type (Off, On)
p3 Event type (see the table below)
P4 Source element number (see the table
below)
p5 Event details (see the table below)
p6 Operation mode (see the table below)
p7 Action type (see the table below)
p8 Source element number (see the table
below)
p9 Action detail 1 (see the table below)
p10 Action detail 2 (see the table below)
p11 Action detail 3 (see the table below)
p3
Event Type
Value
Internal Switch
SW
Remote control
DI
input
Relay (DO channel) DO
Alarm
AlarmIO
(I/O channel)
Alarm
AlarmMath
(math channel)
Alarm
AlarmCom
(communication
channel)
Alarm
AlarmAll
Device status
Status
1
Device status
Status
Device status [GX/
Status
1
GP]
Device status
Status
Timer
Timer
Match time timer
MatchTimeTimer 1 to 12
User function
User function
1 Valid when the advanced security function (/AS) is enabled.
P4
p5
p6
Source
Event details
Operation
Element
mode
Number
1 to 100
-
Rising,
Falling, Both
Channel
-
Rising,
number
Falling, Both
Channel
-
Rising,
number
Falling, Both
Channel
1 to 4
Rising,
number
Falling, Both
Channel
1 to 4
Rising,
number
Falling, Both
Channel
1 to 4
Rising,
number
Falling, Both
-
-
Rising,
Falling, Both
-
Memory
Rising,
(Record)
Falling, Both
Math
(Math)
-
UserLock
(User lock out)
-
Login
(When logged in)
-
MemMediaErr
(Memory/Media
error)
MeasureErr
(Measurement
error)
CommErr
(Communication
error)
1 to 12
-
Edge
-
Edge
1 or 2
-
Edge