2.5 Output Commands
FChInfo
Outputs Decimal Place and Unit
Information
Outputs decimal place and unit information.
Syntax
FChInfo,p1,p2
p1 First channel
p2 Last channel
Example Output the decimal place and unit information
of channels 0001 to 0003.
FChInfo,0001,0003
Description
If you omit p1 and p2, all channels will be output.
For the output format, see
FSysConf
Queries the System Configuration and
Reconfigures Modules
Queries the System Configuration, Reconfigures Modules,
and Performs Activation.
Query the System Configuration
Syntax
FSysConf
Example Query the System Configuration.
FSysConf
Description
For the output format, see
Reconfigures Modules
Aligns the module configuration settings that are
recognized by the recorder and the actual module
configuration.
Syntax
FSysConf,p1
p1 Module reconfiguration (1)
Example Reconfigure the modules.
FSysConf,1
Activate module
Modules need to be activated when the firmware in
installed modules is updated or when modules are
recalibrated.
Syntax
FSysConf,p1
p1 Activate module (3)
Example Activate modules.
FSysConf,3
Description
p1 = 3 is valid when the advanced security function (/
AS) is enabled.
2-98
page
2-158.
page
2-159.
FBTDevInfo
Bluetooth Device Information Output
[GM]
Outputs the Bluetooth device information of the recorder.
Syntax
FBTDevInfo,p1
p1 Bluetooth device information output (0)
Example Output the Bluetooth device information of the
connected device.
FBTDevInfo,0
Description
p1 can be omitted.
For the output format, see
FReminder
Outputs Reminder Information (/AH)
Outputs reminder information.
Syntax
FReminder,p1
p1 Reminder information designation
ALL
1 or 12 Schedule number
Example Output the reminder information for schedule
number 3.
FReminder,3
Description
This command is valid when the aerospace heat
treatment (/AH) option is enabled.
Omitting p1 is equivalent to specifying all registration
numbers.
For the output format, see
FCtrlData
Control Data Output
Outputs the most recent control data.
Syntax
FCtrlData,p1,p2,p3
p1 Output format
0
ASCII format
1
Binary format
p2 First loop number
p3 Last loop number
Example Output the most recent data of loop number
001
FCtrlData,L001
Description
If you omit p2 and p3, all loop numbers will be output.
Only the information of detected modules will be
output.
The data time outputted is not the time of a
control period but the data acquisition time by a
communication command.
For the ASCII output format, see
For the Binary output format, see
page
2-161.
Specifies all schedule numbers
page
2-162.
page
2-163.
page
2-181.