YOKOGAWA GX10 User Manual page 38

Gx series; gp series; gm series; smartdac+ communication command
Hide thumbs Also See for GX10:
Table of Contents

Advertisement

2.4 Setting Commands
SRecManual
Channel for Recording Manual Sampled
Data
Sets the channel for recording manual sampled data.
Syntax
SRecManual,p1,p2,p3
p1 Number (1 to 50)
p2 Channel type
Off Do not record manual sampled data.
I/O channel
IO
Math Math channel (/MT)
Com Communication channel (/MC)
p3 Channel number
Query
SRecManual[,p1]?
Example Assign the manual sampled data of I/O
channel 0003 to number 2 and record.
SRecManual,2,IO,0003
Description
• You cannot use this command to configure settings
while recording is in progress.
• You cannot use this command to configure settings
while computation is in progress.
• If p2=Off, you cannot set p3.
• You cannot set a channel more than once.
SBatch
Batch Function
Configures the batch function's basic settings.
Syntax
SBatch,p1,p2,p3,p4
p1 Enable or disable (Off, On)
p2 Number of lot number digits (Off, 4, 6, 8)
Off
4
6
8
p3 Auto increment (Off, On)
p4 Recording start screen (Comment,
TextField)
Comment
TextField Text field
Query
SBatch?
Example Enable the batch function. Use 4-digit lot
numbers. Automatically increment the lot
number in the next operation.
SBatch,On,4,On,TextField
Description
You cannot use this command to configure settings
while recording is in progress.
When the multi batch function (/BT) is enabled, p1 is
fixed to On.
2-20
Do not use lot numbers.
4-digit lot number
6-digit lot number
8-digit lot number
Batch comment
STextField
Batch Text
Sets a batch text.
Syntax
STextField,p1,p2,p3
p1 Field number (1 to 24)
p2 Title (up to 20 characters, UTF-8)
p3 Character string (up to 30 characters,
UTF-8)
Query
STextField[,p1]?
Example For field number 3, set the field title to
"OPERATOR" and the character string to
"RECORDER1."
STextField,3,'OPERATOR','RECORD
ER1'
Description
You cannot use this command to configure settings
while recording is in progress.
This command is valid only when the multi batch
function (/BT) is disabled.
SDirectory
Name of Directory to Save Data
Sets the name of the directory to save data.
Syntax
SDirectory,p1
p1 Directory name (up to 20 characters,
ASCII)
Query
SDirectory?
Example Set the directory name to "DATA0."
SDirectory,'DATA0'
Description
For the characters that you can use in the directory
Appendix
name (p1), see
The following character strings cannot be used for
directory names.
Character String
AUX
CON
PRN
NUL
CLOCK
CLOCK$
COM0 to COM9
LPT0 to LPT9
You cannot use a character string that starts or ends
with a period or space for directory names.
SFileHead
File Header
Sets the file header character string.
Syntax
SFileHead,p1
p1 File header (up to 50 characters, UTF-8)
Query
SFileHead?
Example Set the file header to "GX_DATA."
SFileHead,'GX_DATA'
Description
This command is valid only when the multi batch
function (/BT) is disabled.
1.
IM 04L51B01-17EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gm10Gx20Gp20Gp10

Table of Contents