2.4 Setting Commands
p2
p4
p5
Type
Input/
Status output/
output
operation content
type
DI (PID
In
PROG/RESET
control
Pattern number
module or
setting Bin
input type
(Patrn1-2)
DI)
Pattern number
setting Bin
DO (alarm
(Patrn1-4)
or manual)
Pattern number
SW
setting Bin
(Patrn1-8)
Pattern number
setting Bin
(Patrn1-16)
Pattern number
setting Bin
(Patrn1-32)
Pattern number
setting Bin
(Patrn1-64)
Pattern number
setting Bin
(Patrn1-99)
Pattern number
setting Bcd (1 digit)
Pattern number
setting Bcd (2 digit)
Hold operation
Advance operation ADVANCE_ACT
Start of program
operation
Stop of program
operation
HOLD operation
with SELECT
ADVANCE
operation with
SELECT
Stop of program
operation with
SELECT
Stop of program
operation with
SELECT
All loop control
operation stop
All loop control
operation start
AUTO/MAN Switch
(A/M)
REMOTE/LOCAL
Switch (R/L)
STOP/RUN Switch
(S/R)
Switch to REMOTE
(REM)
Switch to LOCAL
(LCL)
Switch to Cascade
(CAS)
Switch to AUTO
(AUTO)
Switch to MAN
(MAN)
Target setpoint
number Bin
(SPNo1-2)
Target setpoint
number Bin
(SPNo1-4)
Target setpoint
number Bin
(SPNo1-8)
Target setpoint
number Bcd (1
digit)
2-92
p5
p7
Number
of used
Option strings
channels
PRG_RST_ACT
-
1
PTNNO_BIN_1-
-
1
2_W
PTNNO_BIN_1-
-
2
4_W
PTNNO_BIN_1-
-
3
8_W
PTNNO_BIN_1-
4
-
16_W
PTNNO_BIN_1-
-
5
32_W
PTNNO_BIN_1-
6
-
64_W
PTNNO_BIN_1-
-
7
99_W
PTNNO_
4
-
BCD_1Digi_W
PTNNO_
-
8
BCD_2Digi_W
HOLD_ACT
-
1
-
1
PRG_RUN_ACT
-
1
PRG_STOP_
-
1
ACT
SEL_HOLD_
Auxiliary
1
ACT
parameters
p6 to p9 are
SEL_ADVANCE_
1
available.
ACT
SEL_PRG_
1
RUN_ACT
SEL_PRG_
1
STOP_ACT
ALL_LP_STOP_
LP
1
ACT
ALL_LP_
LP
1
START_ACT
A-M_ACT
LP
1
R-L_ACT
LP
1
S-R_ACT
LP
1
REM_ACT
LP
1
2
LCL_ACT
1
LP
2
CAS_ACT
1
LP
2
AUTO_ACT
LP
1
MAN_ACT
LP
1
SPNO_BIN_1-
LP
1
2_W
SPNO_BIN_1-
2
LP
4_W
SPNO_BIN_1-
LP
3
8_W
SPNO_
LP
4
BCD_1Digi_W
p2
p4
p5
Type
Input/
Status output/
output
operation content
type
DO
Out
Pattern number
monitoring Bin
(for
(Patrn1)
manual)
Pattern number
SW
monitoring Bin
(Patrn1-3)
(for
Pattern number
manual)
monitoring Bin
(Patrn1-7)
Pattern number
monitoring Bin
(Patrn1-15)
Pattern number
monitoring Bin
(Patrn1-31)
Pattern number
monitoring Bin
(Patrn1-63)
Pattern number
monitoring Bin
(Patrn1-99)
Pattern number
monitoring Bcd (1
digit)
Pattern number
monitoring Bcd (2
digit)
Segment number
monitoring Bin
(Seg1)
Segment number
monitoring Bin
(Seg1-3)
Segment number
monitoring Bin
(Seg1-7)
Segment number
monitoring Bin
(Seg1-15)
Segment number
monitoring Bin
(Seg1-31)
Segment number
monitoring Bin
(Seg1-63)
Segment number
monitoring Bin
(Seg1-99)
Segment number
monitoring Bcd (1
digit)
Segment number
monitoring Bcd (2
digit)
PROG/RESET
status output
Wait end signal (1
s hold)
Wait end signal (3
s hold)
Wait end signal (5
s hold)
Pattern end signal
(1 s hold)
Pattern end signal
(3 s hold)
Pattern end signal
(5 s hold)
PV event status
Time event status
Wait flag
Hold-on flag
Control status
1
LP = loop number (1 to 652), EVT = PV/time event number (1 to 32)
2
Save behavior on each module. (Example: 001 and 002 are the same.)
1
p5
p7
Number
of used
Option strings
channels
PTNNO_
-
1
BIN_1_R
PTNNO_BIN_1-
2
-
3_R
PTNNO_BIN_1-
-
3
7_R
PTNNO_BIN_1-
4
-
15_R
PTNNO_BIN_1-
-
5
31_R
PTNNO_BIN_1-
6
-
63_R
PTNNO_BIN_1-
-
7
99_R
PTNNO_
4
-
BCD_1Digi _R
PTNNO_
-
8
BCD_2Digi _R
SEGNO_
-
1
BIN_1_R
SEGNO_BIN_1-
-
2
3_R
SEGNO_BIN_1-
-
3
7_R
SEGNO_BIN_1-
-
4
15_R
SEGNO_BIN_1-
-
5
31_R
SEGNO_BIN_1-
-
6
63_R
SEGNO_BIN_1-
-
7
99_R
SEGNO_
-
4
BCD_1Digit_R
SEGNO_
-
8
BCD_2Digit _R
PRG_RST_R
1
-
WAIT_
-
1
END_1s_R
WAIT_
-
1
END_3s_R
WAIT_
-
1
END_5s_R
PTN_END_1s_R
-
1
PTN_END_3s_R
-
1
PTN_END_5s_R
1
-
PV_EVENT_R
1
EVT
TIME_EVENT_R
EVT
1
WAIT_CONT_R
-
1
HOLD_CONT_R
-
1
RUN_STOP_R
-
1