2.11 Format of the Data Block of Binary Output
2-182
Data Time
Item (Number of Bits)
Year (8 bits)
Month (8 bits)
Day (8 bits)
Hour (8 bits)
Minute (8 bits)
Second (8 bits)
Millisecond (16 bits)
Additional Information (64 bits)
Bit 0: Daylight saving time (0: standard time; 1: daylight saving time)
Loop Number (16 bits)
001 to 692
Data Information (8 bits)
Indicates the data information (or the module status.)
0: Not used, 1: No data, 2: Normal, 3: Luck of data/Module not installed.
PVERR (8 bits)
Indicates the PV error.
Bit
Value
Description
0 to 4
0
No error
1
Skip
2
+OVER
3
-OVER
4
+Burnout
5
-Burnout
6
A/D error
7
Invalid data
5
0
No A/D calibration value error
1
A/D calibrattion value error
6
0
No RJC error
1
RJC error
7
0
Reserved
SPERR (8 bits)
Indicates the SP error.
Bit
Value
Description
0 to 4
0
No error
1
Skip
2
+OVER
3
-OVER
4
+Burnout
5
-Burnout
6
A/D error
7
Invalid data
5
0
No A/D calibration value error
1
A/D calibration value error
6
0
No RJC error
1
RJC error
7
0
Reserved
Value
0 to 99
1 to 12
1 to 31
0 to 23
0 to 59
0 to 59
0 to 999