Addcon - Cisco MGX 8850 PXM1E Software Configuration Manual And Command Reference

Ausm software
Hide thumbs Also See for MGX 8850 PXM1E:
Table of Contents

Advertisement

addcon

addcon
Add Connection
Use the addcon command to configure one end of an SPVC connection on a port on the current AUSM
card.
This software release supports double-ended and single-ended provisioning. Double-ended provisioning
requires that you configure the slave end of the SPVC first, and then configure the master end of the
SPVC. You can configure both slave and master endpoints for double-ended provisioned connections
using the addcon command.
Single-ended provisioning allows you to configure only the master end of the connection, and the master
end automatically configures the slave end. This software release supports single ended provisioning
where the master end point is defined on another device and the AUSM card hosts the slave connection.
This software release does not support single-ended provisioning with a master on the local AUSM card.
When you add a connection, the software checks the configuration at the remote end to be sure the
remote connection configuration is compatible. If the local and remote configuration parameters are not
compatible, the connection is not added.
Syntax:
addcon <port_number> <vpi> <vci> [-ct <ConnectionType>] [-contp <ControllerType>]
[-st <ServiceClassTtype>] [-master <MasterShip>] [-rmc <RemoteConnId>] [-abrtype <ABRType>]
[-abrpcr <ABRPCR>] [-abrmcr <ABRMCR>] [-osub <OvrSubFlag>] [-ipcu <IngrPercentUtil>]
[-epcu <EgrPercentUtil>] [-upce <UpcEnable>] [-scrp <SCRPolicing>] [-ccdv <CDVT[0+1]>]
[-cte <CLPTagEnable>] [-dis <DiscardOption>] [-pcr01 <IngrUpcPCR[0+1]>] [-scr <IngrUpcSCR>]
[-cbs <MaxBurstSize>] [-maxcost <MaxCost>] [-rtngpri <RoutingPriority>] [-type <restrictedType>]
[-rpcr <RemotePCR>] [-rscr <RemoteSCR>] [-rmcr <RemoteMCR>] [-rcbs <RemoteMaxBurstSize>]
If the addcon command fails and displays the "Failed to update disk" message, it could be that the PNNI
Note
controller has not been added on the PXM1E card. For information on adding the PNNI controller, refer
to the Cisco MGX 8850 (PXM1E) and MGX 883Cisco MGX 8850 (PXM1E) and MGX 8830 Software
Configuration Guide, Release 3.
Syntax Description
port_num
vpi
vci
-ct
Cisco AUSM Software Configuration Guide and Command Reference for MGX 8850 (PXM1E) and MGX 8830
4-10
Enter the port number for the ATM port or IMA group to which you will add
the connection. To display a list of configured ports, enter the dspports
command.
Enter a VPI number in the range from 0 to 255.
Enter a VCI number in the range from 35 to 65535. For virtual path connections,
enter *.
Enter a connection type:
VCC = 0
VPC range = 1 to 1000
Chapter 4
AUSM Command Reference
Release 3, Part Number 78-14254-01 Rev. A0, October 2002