LAG Commands
selection-criteria
Syntax
selection-criteria [highest-count | highest-weight] [slave-to-partner]
no selection-criteria
Context
config>lag
Description
This command specifies which selection criteria should be used to select the active sub-group.
Default
highest-count
Parameters
highest-count — Specifies sub-group with the highest number of eligible members.
highest-weight — Specifies sub-group with the highest aggregate weight.
best-port — Selection criteria used with "power-off" mode of operation. The sub-group containing the port
with highest priority port. In case of equal port priorities the sub-group containing the port with the
lowest port-id is taken
slave-to-partner — The slave-to-partner keyword specifies that it, together with the selection criteria,
should be used to select the active sub-group. An eligible member is a lag-member link which can
potentially become active. This means it is operationally up (not disabled) for use by the remote side.
The slave-to-partner parameter can be used to control whether or not this latter condition is taken into
account.
standby-signalling
Syntax
standby-signalling {lacp | power-off}
no standby-signalling
Context
config>lag
Description
This command specifies how the state of a member port is signalled to the remote side when the status
corresponding to this member port has the standby value.
sub-ring
Syntax
sub-ring {virtual-link | non-virtual-link}
[no] sub-ring
Context
config>eth-ring>sub-ring
This command additionally specifies this ring-id to be sub-ring as defined in G.80312. By declaring this ring
as a sub-ring object, this ring will only have one valid path and the sub-ring will be connected to a major
ring or a VPLS instance. The virtual-link parameter declares that a sub-ring is connected to another ring and
that control messages can be sent over the attached ring to the other side of the sub-ring. The non-virtual
channel parameter declares that a sub-ring may be connected to a another ring or to a VPLS instance but that