Alcatel-Lucent 7710 SR Configuration Manual page 317

Service router os interface configuration guide
Hide thumbs Also See for 7710 SR:
Table of Contents

Advertisement

config>port>tdm>ds1>channel-group>cisco-hdlc
config>port>tdm>ds3>cisco-hdlc
config>port>tdm>e1>channel-group>cisco-hdlc
config>port>tdm>e3>cisco-hdlc
Description
This command configures the number of keepalive intervals that must pass without receiving a keepalive
packet before the link is declared down. It is expected that the nodes at the two endpoints of the cHDLC link
are provisioned with the same values.
Default
3
down-count — Specifies the number of keep alive intervals that must pass without receiving a keep alive
packet before the link is declared down.
Values
encap-type
Syntax
encap-type {atm | bcp-null | bcp-dot1q | ipcp | ppp-auto | frame-relay | wan-mirror |cisco-
hdlc| cem}
Context
config>port>tdm>ds1>channel-group
config>port>tdm>ds3
config>port>tdm>e1>channel-group
config>port>tdm>e3
Description
This command configures the encapsulation method used to on the specified port, path, or channel. This
parameter can be set on both access and network ports.
When the encap-type is set to ATM the CRC, timeslots, scrambling (if applicable), and idle-cycle-flags are
set to ATM defaults respectively. When the encap-type is changed from ATM, those parameters are set to
their non-ATM defaults.
When the encap-type is ATM, ATM sub-layer verification (GR-1248-CORE, Generic Requirements for
Operations of ATM Network Elements (NEs)) is automatically enabled. When ATM PLCP cell mapping is
used, the results of this verification include:
• PLCP Severely Errored Framing Seconds
• PLCP Alarm State
• PLCP Unavailable Seconds Counter
When ATM direct cell mapping is used, the result of the verification includes:
• Out of Cell Delineation (OCD) event count. The OCD event count is described in RFC 2515, Defini-
tions of Managed Objects for ATM Management. Note that multiple events occurring within a second
will be counted as 1 event for ASAP MDAs as a result of a hardware limit.
• Loss of Cell Delineation defect/alarm. The LCD defect/alarm is defined in RFC 2515, Definitions of
Managed Objects for ATM Management. When a path is in an LCD defect state, the path's operational
status will be down. When a path exits the LCD state, the path's operational status will change to up
(assuming nothing else causes the path to stay down). A trap is raised to indicate the LCD status change.
Also, a P-RDI is sent to indicate the defect to the remote end.
7710 SR OS Interface Configuration Guide
3 — 16
Interface Configuration
Page 291

Advertisement

Table of Contents
loading

Table of Contents