Alcatel-Lucent 7710 SR Configuration Manual page 289

Service router os interface configuration guide
Hide thumbs Also See for 7710 SR:
Table of Contents

Advertisement

section-trace
Syntax
section-trace {increment-z0 | byte value | string string}
Context
config>port>sonet-sdh
Description
This command configures the section trace bytes in the SONET section header to interoperate with some
older versions of ADMs or regenerators that require an incrementing STM ID. You can explicitly configure
an incrementing STM value rather than a static one in the SDH overhead by specifying the z0-increment.
Default
byte 0x1
Parameters
increment-z0 — Configure an incrementing STM ID instead of a static value.
byte value — Set values in SONET header bytes.
Default
Values
string string — Specifies a text string that identifies the section.
Values
speed
Syntax
speed {oc3 | oc12}
no speed
Context
config>port>sonet-sdh
Description
This command configures the speed of a SONET/SDH port as either OC3 or OC12. The framer for this
MDA operates in groups of four. Changing the port speed for a port requires resetting the framer and causes
a slight disruption on all four ports. The first framer controls ports 1,2,3,4, the second framer controls ports
5,6,7,8 etc.
To change the port speed on a SONET/SDH port, the port must be administratively shut down and all
channels must be removed. When the port speed is changed, the default channel configuration is recreated.
The no form of this command reverts back to default.
Default
oc12
Parameters
oc3 — set the speed of the port to OC-3.
oc12 — Set the speed of the port to OC-12.
suppress-lo-alarm
Syntax
[no] suppress-lo-alarm
Context
config>port>sonet-sdh
7710 SR OS Interface Configuration Guide
0x1
0 — 255 or 0x00 — 0xFF
A string up to 16 bytes.
Interface Configuration
Page 263

Advertisement

Table of Contents
loading

Table of Contents