Alcatel-Lucent 7710 SR Configuration Manual page 288

Service router os interface configuration guide
Hide thumbs Also See for 7710 SR:
Table of Contents

Advertisement

SONET/SDH Port Commands
report-alarm
Syntax
[no] report-alarm [loc] [lais] [lrdi] [ss1f] [lb2er-sd] [lb2er-sf] [slof] [slos] [lrei]
Context
config>port>sonet-sdh
Description
This command enables logging of SONET (SDH) line and section alarms for a SONET-SDH port. Only line
and section alarms can be configured in the SONET/SDH context, for path alarms see the sonet-sdh>path
context.
The no form of this command disables logging of the specified alarms
Parameters
loc — Reports a loss of clock which causes the operational state of the port to be shut down.
Default
lais — Reports line alarm indication signal errors. When configured, lais alarms are raised and cleared.
Default
lrdi — Reports line remote defect indication errors. LRDI's are caused by remote LOF, LOC, LOS. When
configured, lrdi alarms are raised and cleared.
Default
ss1f — Reports section synchronization failure which is detected when the S1 byte is not consistent for 8
consecutive frames. When configured, ss1f alarms are raised and cleared.
Default
lb2er-sd — Reports line signal degradation BER (bit interleaved parity) errors. Use the threshold command
to set the error rate(s) that when crossed determine signal degradation and signal failure. When
configured, lb2er-sd alarms are raised and cleared.
Default
lb2er-sf — Reports line signal failure BER errors. Use the threshold command to set the error rate(s) that
when crossed determine signal degradation and signal failure.When configured, lb2er-sf alarms are
raised and cleared.
Default
slof — Reports section loss of frame errors. When configured, slof alarms are raised and cleared.
Default
slos — Reports a section loss of signal error on the transmit side. When configured, slos alarms are raised
and cleared.
Default
lrei — Reports a line error condition raised by the remote as a result of b1 errors received from this node.
When configured, lrei traps are raised but not cleared
Default
Page 262
loc alarms are issued.
lais alarms are not issued.
lrdi alarms are issued.
ss1f alarms are not issued.
lb2er-sd alarms are not issued.
lb2er-sf alarms are issued.
slof alarms are issued.
slos alarms are issued.
lrei traps are not issued.
7710 SR OS Interface Configuration Guide