Wiring the FM 453
Connection of the
The procedure for connecting the input signals to the FM 453 is explained for
Input Signals
the READY2 signal by way of example.
There are two methods for connecting the input signals:
Power from
Figure 4-13 shows how to connect the standby signal to connector X1 of the
Auxiliary Voltage
FM 453 (e.g. SIMODRIVE 611 drive on channel 1 of the FM).
L+

Fig. 4-13 Connection of Standby Signal, Power from Auxiliary Voltage L+

Power from the
Figure 4-14 shows how to power the standby signal from the drive unit.
External Signal
Source

Fig. 4-14 Actuation of the Standby Signal, Power Supply from the Drive Unit

4-26
with power supplied from the auxiliary voltage L+
with power supplied from the external signal source
Actuation of standby signal by high-side switch or relay contact
FM
X1
9
29
30
47
48
Actuation of standby signal by high-side switch or relay contact
FM
X1
9
47
48
High-side switch
READY2 /channel
or relay contact
1
74
73
2L+
M2
e.g. SIMODRIVE
611
Drive unit
READY2 /channel
1
M2