Table 5-6 Db Structure - Increments - Siemens SIMATIC FM 453 Manual

Servo drive / step drive positioning module
Hide thumbs Also See for SIMATIC FM 453:
Table of Contents

Advertisement

5.3.2
Increments
DB Structure
Table 5-6 gives you a general view of the structure of the "Increments" data
block (DB-SM).
DB No.: 1230 for channel 1
DB No.: 1530 for channel 2
DB No.: 1830 for channel 3
Table 5-6
DB Structure – Increments
Address
Variable Type
0
WORD
2
WORD
4
DWORD
8
WORD
10
WORD
1
12
2 STRING
SM
16
DWORD
453
20
4 CHAR
0
24
DWORD
1 – 3
28
WORD
0/1
30
WORD
32
DWORD
0 – 10
36
DWORD
0 – 10
Input of Values
Values are input in the increments menu of the "Parameterize FM 453" para-
meterization tool.
Fig. 5-6
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
Value
Significance of the Variables
DB header (36 Byte)
Rack slot
DB No. (
1000)
Reserved
Error No. (from FM)
Channel number
DB identifier/type
Module identifier
Version number/block number
Measurement-system grid per MD7
Parameter (DB) backup
Reserved
9
Increment 1
9
Increment 2
to
increment 100
Entering Values for Incremental Dimensions
Defining Parameters of the FM 453
Comment
Module address
As in DB header
With MMI services
2 ASCII characters
FM 453
(DB structure)
Unit of measurement
Job via MMI
see Section 9.2.4
5-21

Advertisement

Table of Contents
loading

Table of Contents