Table 4-11Pinout Of The Front Connector - Siemens SIMATIC FM 453 Manual

Servo drive / step drive positioning module
Hide thumbs Also See for SIMATIC FM 453:
Table of Contents

Advertisement

Connector Pinout
Connector identifier:
Connector type:
Table 4-11
Termi-
nal
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
1) In applications using encoders, 1L+ with reference 1M must always be connected
2) If this channel is not utilized, the associated auxiliary voltage must not be connected.
3) Terminals 19, 24, 47 and 48 (reference potential 2M) are connected together on the
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
X1
48-pin S7 front connector with single-wire terminals
Pinout of the Front Connector
Name
Significance
M
Contains cable bridge for detection of the plugged in con-
nector
nector
FE_X1
1L+
24 V DC auxiliary voltage for sensor supply
Terminals 3, 4 and 5 are connected together on the module.
1L+
1L+
1NL
Input, zero position signal from channel 1
2NL
Input, zero position signal from channel 2
3NL
Input, zero position signal from channel 3
1READY2
Input, standby signal 2 from channel 1
2READY2
Input, standby signal 2 from channel 2
3READY2
Input, standby signal 2 from channel 3
M1
Reference potential for auxiliary voltage 1L+
Terminals 12, 13 and 14 are connected together on the
M1
module.
module
M1
1I0
Digital input 0 from channel 1
1I1
Digital input 1 from channel 1
1I2
Digital input 2 from channel 1
1I3
Digital input 3 from channel 1
M2
Reference potential for auxiliary voltage 2L+ to 4L+
2I0
Digital input 0 from channel 2
2I1
Digital input 1 from channel 2
2I2
Digital input 2 from channel 2
2I3
Digital input 3 from channel 2
M2
Reference potential for auxiliary voltage 2L+ to 4L+
3I0
Digital input 0 from channel 3
3I1
Digital input 1 from channel 3
3I2
Digital input 2 from channel 3
3I3
Digital input 3 from channel 3
to a 24 V auxiliary voltage.
module.
Wiring the FM 453
1)
3)
3)
4-23