5.2
Getting Started with "Parameterize FM 453"
Prerequisites
You have installed the software on your programming device/PC, as de-
scribed in Section 5.1.
Configuration
Before you can configure your system, you must create a project in which to
save the parameters. You will find further information on how to configure
modules in your user manual Standard Software for S7 and M7, STEP 7. The
description below outlines only the most important steps.
1. Start the SIMATIC Manager and open your project.
2. Insert a SIMATIC 400 station in the menu Insert Station.
3. Select the SIMATIC 400 station. Call up the S7 hardware configuration
4. Select a rack and assign it.
5. Select the FM 453 positioning module with the correct order number from
6. Double-click a module to configure it.
Fig. 5-2
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
from the menu Edit Open Object.
the module catalog, and insert it in the hardware table as appropriate for
your configuration.
The Properties dialog box appears.
Getting Started with "Parameterize FM 453"
Defining Parameters of the FM 453
5-3