Description of Functions
9.8
Digital Inputs/Outputs (Job No. 101)
Overview
Four digital inputs and four digital outputs of the FM 453 can be used specifi-
cally to a given application.
The conventions and parameterization for this purpose are defined in the ma-
chine data MD34 to MD36.
The signals are processed in the FM cycle.
The signal status of the digital inputs and outputs can be recognized by read-
back (job no. 101).
Function
Table 9-13 shows you the functions assigned to each digital I/O.
Parameters
Table 9-13
34
35
1) see Section 5.3.1, Dependencies
2) Signal length
Level adjustment
36
9-92
Function Parameters for Digital I/Os
MD
Designation
1)
Digital inputs
I0
0
1
2
3
4
5
6
1)
Digital outputs
Q0
0
1
2
3
4
5
7
2 FM cycle
MD
Designation
Input adjustment
8 = I0 inverted
9 = I1 inverted
10 = I2 inverted
11 = I3 inverted
Data Type, Bit Array/Meaning
I1
I2
I3
8
16
24 = External start
9
17
25 = Enable input
10
18
26 = External block change
11
19
27 = Set actual value on-the-fly
12
20
28 = Measurement (inprocess mea-
surement,
length measurement
13
21
29 = Reference point switch for
reference point approach
14
22
30 = Reversing switch for
reference point approach
Q1
Q2
Q3
8
16
24 = Position reached, stop
9
17
25 = Axis movement forwards
10
18
26 = Axis movement backwards
11
19
27 = Change M97
12
20
28 = Change M98
13
21
29 = Start enable
15
23
31 = Direct output
Value/Meaning
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
2)
2)
)
2)
2)
Comments
Front edge al-