Man-Machine Interface
Table 8-1
Analysis of the User DB by the User Program, continued
OP 17
Triggered by
Triggered by
Byte.Bit
Event
406.6 = 1
SK "Tipp"
406.0 = 1
SK "Steu"
406.1 = 1
SK "Refpk"
406.2 = 1
SK "SMR"
406.3 = 1
SK "MDI"
406.4 = 1
SK "AutoE"
406.5 = 1
SK "Autom"
40.14
TF "software
limit switch
off"
42.13 = 1
TF "Restart
axis"
42.9 = 1
TF "Delete
distance to go"
390.1 = 1
SK "read"
42.8 = 1
SK "active"
390.0 = 1
SK "set"
406.15 = 1
SK "Res"
SK "Ack"
406.14 = 1
SK = Soft key, TF = Text field
8-8
User Program
Set in User DB
(Byte.Bit)
Transfer data for "Jog" operating mode
and the "Jog" operating mode to the FM
Transfer data for the "Control" operating
mode and the "Control" operating mode
to the FM
Transfer the "Reference point approach"
operating mode to the FM
Transfer data for "Incremental relative"
operating mode and the incremental rel-
ative mode to the FM
Transfer "MDI" operating mode to the
FM
Transfer "Automatic single block" oper-
ating mode to the FM
Transfer "Automatic" operating mode to
the FM
In case of modification, transfer "Soft-
ware limit switch disable" yes/no to the
FM
Transfer "Restart axis" memory bit to
the FM
Transfer "Delete distance to go"
memory bit to the FM
Read MD No. from the user DB, retrieve
its value from the FM and enter into the
user DB
Transfer "activate MD" to the FM
Transfer MD No. and its value from the
user DB to the FM
Error acknowledgment "Res" in FM 453
(diagnostic interrupt)
Error acknowledgment "Quit" in the
FM 453 (data errors, operator control/
guidance errors)
FM 453 Servo Drive / Step Drive Positioning Module
Delete
Function
Byte.Bit
406.6
406.0
406.1
406.2
406.3
406.4
406.5
42.13
42.9
390.1
42.8
390.0
406.15
390.13
406.14
390.14
390.15
C79000-G7076-C453-01