Writing Traversing Programs
Chapter
Overview
10.1
10.2
10.3
10.1 Traversing blocks
Block Structure
The following Figure gives you an overview of the structure of traversing
blocks.
/
N
G1 – G function of first function group
G2 – G function of second function group
G3 – G function of third function group
X/t – Position/dwell time
F
M1 – M function of first function group
M2 – M function of second function group
M3 – M function of third function group
D
L
P
10-2
/
N G1 G2 G3
X/t
5
90
500 000
6
91
7
.
.
.
45
46
In Section
Traversing Blocks
Program Execution and Direction of Processing
Block Transitions
/ N G1 G2 G3
X/t
– Identifier for skipped block
– Block number
– Speed
– Tool offset number
– Call a program as a subprogram
– Number of subprogram calls
F
M1 M2 M3
D
L
100 000 10
2
You Will Find
F
M1 M2 M3 D
L
see
Table 10-1
see
Table 10-2
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
P
Start of
program =
lowest
block
number
End of pro-
gram =
M2 or M30
On Page
10-2
10-15
10-15
P