Defining Parameters of the FM 453
5.3
Parameter Data
What Can I Para-
You can parameterize the following data storage areas:
meterize?
This data is stored in data blocks (DBs) within the numerical range (not includ-
ing user data):
from 1001 to 1239 for channel 1
from 1301 to 1539 for channel 2
from 1601 to 1839 for channel 3
The MD, SM, TO and NC data blocks are transferred to the FM 453 and re-
side in memory there.
Parameterization of SM, TO and NC may be omitted if the associated func-
tions are not used.
The user data block must be stored in the CPU. Only then can it be filled
with data online (see Section 6).
Parameterization data (except for user data) can also be created, edited and
saved offline on the PG.
5-6
Machine data (MD)
Increment sizes (SM)
Tool offset data (TO)
Traversing programs (NC)
User data (user data blocks)