9.8.1
Function Description for Digital Inputs
External Start
The control signals of the axis include the start signal which triggers a posi-
tioning operation in "Reference point approach", "MDI" and "Automatic"
modes. A logical OR is established with the "External Start" digital input and
the control signal (ST).
External start is connected to digital input I1.
Example
ST
dig. "External start" input
Input I1 not inverted (MD36)
1
2
3
Minimum signal length at the digital input:
Enable Input
The enable input signal must be set, if defined in MD34, for a positioning
operation/movement/output of the axis to take place. A reset stops the move-
ment (external movement enable).
Example
R+ or R–
Enable
1
2
3
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
1
2
In the "Jogging" and "Control" modes, the movement of the axis pro-
ceeds as long as the AND link continues between the control signal
(R+/R–) and the enable input.
1
3
&
2
In the other modes, note the following:
If the enable input is still not enabled after a start edge, the start edge is
stored internally and "waiting for enable" is indicated by the checkback
signals. When the input is set, movement begins and the stored Start edge
is deleted (a Stop likewise deletes the stored Start edge).
Description of Functions
3
1
Control signal (Start)
Input I1 inverted (MD36)
2 FM cycle