Siemens SIMATIC FM 453 Manual page 296

Servo drive / step drive positioning module
Hide thumbs Also See for SIMATIC FM 453:
Table of Contents

Advertisement

Description of Functions
Rotary Axis
The end position of MD
When traveling into the working range (e.g. end position was previously
switched off), the shortest path is always chosen.
If both default values are parameterized the software limit switches are inac-
tive.
9.10 Process Interrupts
Overview
Process interrupts are interrupts that quickly signal states in the current pro-
cess to the user program.
The appropriate setting in the machine data (MD5) specifies which signals
are to be quickly communicated to the user program.
Process-Interrupt
The process interrupt is generated by way of machine data item MD5:
Generation
Hint to the User
You must program the interrupt processing routine in OB40.
The prerequisite is that process-interrupt signaling must have been activated
as part of the environment definition (see Chapter 5).
9-96
may be greater than MD
start
MD
Designation
5
Process-interrupt generation
(data type - bit field)
stop.
Significance
0 = Position reached
1 = Length measurement completed
3 = Change block on-the-fly
4 = Measurement on-the-fly
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01

Advertisement

Table of Contents
loading

Table of Contents