◆ F6: Communication Option Card

These parameters configure communication option cards and communication fault detection methods.
F6-01: Operation Selection after Communications Error
Determines drive operation when a communication error occurs.
No.
F6-01
Setting 0: Ramp to stop (uses the deceleration ramp set to C1-02)
Setting 1: Coast to stop
Setting 2: Fast Stop (uses the Fast Stop ramp set to C1-09)
Setting 3: Alarm only (continue operation)
F6-02: External Fault from Communication Option Detection Selection
Determines the detection method of an external fault (EF0) initiated by a communication option card.
No.
F6-02
External Fault from Communication Option Detection Selection
Setting 0: Always detected
Setting 1: Detection during run only
F6-03: External Fault from Communication Option Operation Selection
Determines drive operation when an external fault is initiated by a communication option (EF0).
No.
F6-03
External Fault from Communication Option Operation Selection
Setting 0: Ramp to stop (uses the deceleration ramp set to C1-02)
Setting 1: Coast to stop
Setting 2: Fast Stop (uses the Fast Stop ramp set to C1-09)
Setting 3: Alarm only (continue operation)
F6-04: bUS Error Detection Time
Sets the delay time for bUS error detection.
No.
F6-04
F6-06: Torque Limit Selection from Communications Option
Selects whether torque limit values are assigned to the drive from the network.
No.
F6-06
Setting 0: Disabled
Setting 1: Enabled
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Parameter Name
Operation Selection after Communications Error
Parameter Name
Parameter Name
Parameter Name
bUS Error Detection Time
Parameter Name
Torque Limit Selection from Communications Option
5.6 F: Option Settings
Setting Range
Default
0 to 3
Setting Range
Default
0 or 1
Setting Range
Default
0 to 3
Setting Range
Default
0.0 to 5.0 s
Setting Range
Default
0, 1
1
0
1
5
2.0 s
0