Drive Derating Data - YASKAWA L1000A Technical Manual

200 v class: 1.5 to 110 kw (2 to 150 hp) 400 v class: 1.5 to 315 kw (2 to 500 hp) 600 v class: 1.5 to 160 kw (2 to 250 hp)
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

A.6 Drive Derating Data
The drive can be operated at above the rated temperature, altitude, and default carrier frequency by derating the drive
capacity.
◆ Rated Current Depending on Carrier Frequency
Table A.7
shows the drive output current depending on the carrier frequency settings.
The 2 kHz value is equal to the Normal Duty rated current. If the carrier frequency is increased above 2 kHz in ND, the
rated output current is reduced.
The 8 kHz and 5 kHz values are equal to the Heavy Duty rated current. They define the value up to which the carrier
frequency can be increased in HD without a current derating (default HD carrier frequency is 2 kHz). Increasing the
carrier frequency above 8 kHz or 5 kHz reduces the rated output current.
Use the data in
Table A.7
to linearly calculate output current values for carrier frequencies not listed in the tables.
Three-Phase 200 V Class
Rated Current (A)
Model
CIMR-LU
2 kHz
8 kHz
20008
8
8
20011
11
11
20014
14
14
20018
17.5
17.5
20025
25
25
20033
33
33
20047
47
47
20060
60
60
20075
75
75
20085
85
85
20115
115
115
20145
145
145
20180
180
180
20215
215
215
20283
283
283
20346
346
346
20415
415
415
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Table A.7 Carrier Frequency and Current Derating
Three-Phase 400 V Class
Model
CIMR-LU
15 kHz
2 kHz
6.4
40005
4.8
8.8
40006
5.5
11.2
40007
7.2
14
40009
9.2
20
40015
14.8
26.4
40018
18
37.6
40024
24
48
40031
31
53
40039
39
60
40045
45
81
40060
60
116
40075
75
144
40091
91
172
40112
112
226
40150
150
277
40180
180
332
40216
216
40260
260
40304
304
40370
370
40450
450
40605
605
Rated Current (A)
Model
CIMR-LU
8 kHz
15 kHz
4.8
2.9
50003
5.5
3.3
50004
7.2
4.3
50006
9.2
5.5
50010
14.8
8.9
50013
18
10.8
50017
24
14.4
50022
31
18.6
50027
39
23.4
50032
45
27
50041
60
36
50052
75
45
50062
91
55
50077
112
78
50099
150
105
50130
180
126
50172
216
151
50200
A.6 Drive Derating Data
Three-Phase 600 V Class
Rated Current (A)
2 kHz
8 kHz
15 kHz
3.5
3.5
2.1
4.1
4.1
2.5
6.3
6.3
3.8
9.8
9.8
5.9
12.5
12.5
17
17
22
22
27
27
32
32
41
41
52
52
62
62
77
53.9
99
39.6
130
52
172
113.9
200
A
385

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents