B.3 Parameter Table

◆ S: Elevator Parameters

This section describes various functions and faults needed to operate an elevator application: braking sequence, slip
compensation for elevators, start/stop optimization, Rescue Operation, and elevator-related faults.
S1: Brake Sequence
No. (Addr.)
Name
S1-01
Zero Speed Level at Stop
(680H)
S1-02
DC Injection Current at Start
(681H)
S1-03
DC Injection Current at Stop
(682H)
S1-04
DC Injection/Position Lock Time
(683H)
at Start
S1-05
DC Injection/Position Lock Time
(684H)
at Stop
S1-06
Brake Release Delay Time
(685H)
S1-07
Brake Close Delay Time
(686H)
S1-10
Run Command Delay Time
(687H)
S1-11
Output Contactor Open Delay
(688H)
Time
S1-12
Motor Contactor Control During
(6E0H)
Auto-Tuning
<39>
S1-26
(6D7H)
Emergency Stop Start Level
<44>
<5> Default setting is determined by the control mode (A1-02).
<39> Available in drive software versions PRG: 7016 or later.
<44> Available in drive software versions PRG: 7017 or later.
424
All Modes
Determines the speed to begin applying DC Injection (or Position Lock) when the drive is
ramping to stop (b1-03 = 0). Set as a percentage of the maximum output frequency (E1-04).
V/f
OLV
Determines the amount of current to use for DC Injection at start. Set as a percentage of the
drive rated current.
V/f
OLV
Determines the amount of current to use for DC Injection at stop. Set as a percentage of the
drive rated current.
All Modes
Determines how long the drive should perform DC Injection at start. In CLV and CLV/PM,
S1-04 determines how long Position Lock should be performed. A setting of 0.00 disables
S1-04.
All Modes
Determines how long the drive should perform DC Injection at stop. In CLV and CLV/PM,
S1-05 determines how long Position Lock should be performed. A setting of 0.00 disables
S1-05.
All Modes
Determines the delay time between the start of DC injection/Position Lock and setting the brake
control command (H2- = 50) in order to release the brake at the beginning of the ride.
All Modes
Determines the delay time between reaching Zero Speed (S1-01) and resetting the brake control
command (H2- = 50) in order to apply the brake at the end of the ride.
All Modes
Sets the time that must pass after the Up/Down command is entered until the drive internal Run
command is set and the ride is started.
All Modes
Determines the delay time between shutting off the output of the drive and resetting the
contactor control command (H2- = 51) in order to release the motor contactor after a ride
has finished.
All Modes
Determines the state of the output contactor control command (H2- = 51) during
Auto-Tuning.
0: Disabled
1: Enabled
2: Enabled during Auto-Tuning and HBB
Note: Setting 2 is available in the control mode CLV or CLV/PM for drives with software
versions PRG: 7017 or later. The setting is 0 or 1 for software version PRG: 7016.
V/f
OLV
Sets the Emergency Stop Start Level as a percentage of the Maximum Output Frequency.
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Description
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
Setting
common_
Default:
<5>
TMonly
Min: 0.000%
Max: 9.999%
common_
Default: 50%
TMonly
Min: 0%
Max: 100%
common_
Default: 50%
TMonly
Min: 0%
Max: 100%
common_
TMonly
Default: 0.40 s
Min: 0.00 s
Max: 10.00 s
common_
TMonly
Default: 0.60 s
Min: 0.00 s
Max: 10.00 s
common_
Default: 0.20 s
TMonly
Min: 0.00 s
Max: 10.00 s
common_
Default: 0.10 s
TMonly
Min: 0.00 s
Max: [S1-05]
common_
Default: 0.10 s
TMonly
Min: 0.00 s
Max: 1.00 s
common_
TMonly
Default: 0.10 s
Min: 0.00 s
Max: 1.00 s
common_
TMonly
Default: 0
Min: 0
Max: 2
Default: 10.0%
common_
TMonly
Min: 0.0%
Max: 100.0%
Page
258
258
258
258
259
259
259
259
259
259
260