◆ H: Multi-Function Terminals

H parameters assign functions to the multi-function input and output terminals.
H1: Multi-Function Digital Inputs
No.(Addr.)
Name
H1-03
Terminal S3 Function Selection
(400H)
H1-04
Terminal S4 Function Selection
(401H)
H1-05
Terminal S5 Function Selection
(402H)
H1-06
Terminal S6 Function Selection
(403H)
H1-07
Terminal S7 Function Selection
(404H)
H1-08
Terminal S8 Function Selection
(405H)
<19> With the speed reference priority d1-18 is set to 0 or 3, the default settings for parameters H1-03 to H1-07 governing input terminals S3 to S7
are: 24, 14, 3, 4, and 5 respectively. When d1-18 is set to 1 or 2, the default settings for H1-03 to H1-07 become 50, 54, 51, 53, and F
respectively.
H1-
Function
Setting
3
Multi-Step Speed Reference 1
4
Multi-Step Speed Reference 2
5
Multi-Step Speed Reference 3
6
Jog reference selection
408
V/f
OLV
0: Disabled. Torque limit from option card disabled.
1: Enabled. Torque limit from option card enabled.
All Modes
0: Communication-related parameters (F6-) are not reset when the drive is initialized using
A1-03.
1: Reset all communication-related parameters (F6-) when the drive is initialized using
A1-03.
All Modes
Sets the node address.
All Modes
0: Auto-detection
1: 10 kbps
2: 20 kbps
3: 50 kbps
4: 125 kbps
5: 250 kbps
6: 500 kbps
7: 800 kbps
8: 1 Mbps
All Modes
Assigns a function to the multi-function digital inputs.
Refer to page
408
to page
410
for a description of setting values.
Note: Unused terminals should be set to F.
H1 Multi-Function Digital Input Settings
All Modes
When input terminals are set to Multi-Step Speed References 1 through 3, switching combinations of those
terminals will create a multi-step speed sequence using the speed references set in d1-01 through d1-08.
All Modes
Closed: Jog frequency reference (d1-17) selected.
The Jog frequency can be used when the speed reference selection is not assigned to input terminals (b1-01 ≠ 1)
and the speed reference priority is set to use the multi-step speed reference (d1-18 = 0 or 3).
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Description
CLV
CLV/PM
Description
Description
Setting
common_
Default: 0
TMonly
Min: 0
Max: 1
common_
TMonly
Default: 0
Min: 0
Max: 1
Default: 0
common_
TMonly
Min: 0
Max: 126
common_
TMonly
Default: 6
Min: 0
Max: 8
Setting
Default:
<19>
Min: 3
Max: 79
Default:
<19>
Min: 3
Max: 79
Default:
<19>
common_
Min: 3
TMonly
Max: 79
Default:
<19>
Min: 3
Max: 79
Default:
<19>
Min: 3
Max: 79
Default: F
Min: 3
Max: 79
common_
TMonly
common_
TMonly
Page
201
202
Page
203
203
203
203
203
203
Page
203
203
203
203

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents