N: Advanced Performance Set-Up - YASKAWA L1000A Technical Manual

200 v class: 1.5 to 110 kw (2 to 150 hp) 400 v class: 1.5 to 315 kw (2 to 500 hp) 600 v class: 1.5 to 160 kw (2 to 250 hp)
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

No. (Addr.)
Name
L8-77
Oscillation Suppression
(61EH)
L8-88
Safe Disable Operation Mode
(2F5H)
L8-89
(B97H)
Current Monitoring Selection
<44>
L8-99
(B98H)
Current Monitoring Level
<44>
<1> Parameter setting value is not reset to the default value when the drive is initialized.
<4> Default setting is determined by the drive model (o2-04).
<44> Available in drive software versions PRG: 7017 or later.
<48> The default is 2 for 600 V class drive models and models CIMR-LF that are in compliance with IEC/EN 61508 SIL3 Safety Integrity
Level 3.

◆ n: Advanced Performance Set-Up

The n parameters are used to adjust more advanced performance characteristics such as speed feedback detection, Online
Tuning for motor line-to-line resistance, and PM motor control tuning.
n1: Hunting Prevention
No. (Addr.)
Name
n1-08
Leakage Current Vibration Control
(1105H)
Selection
<45>
<45> Available in drive software versions PRG: 7200 or later.
n2: Speed Feedback Detection Control (AFR) Tuning
No. (Addr.)
Name
n2-01
Speed Feedback Detection Control
(584H)
(AFR) Gain
n2-02
Speed Feedback Detection Control
(585H)
(AFR) Time Constant 1
n2-03
Speed Feedback Detection Control
(586H)
(AFR) Time Constant 2
n5: Inertia Compensation
No. (Addr.)
Name
n5-01
Inertia Compensation Selection
(5B0H)
n5-02
Motor Acceleration Time
(5B1H)
n5-03
Inertia Compensation Gain
(5B2H)
n5-07
Speed Feedback Compensation
(170H)
Selection
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Description
All Modes
Used to suppress speed oscillations that occur with an unloaded motor and that have the same
frequency as the output frequency.
All Modes
0: Mode 0
1: Mode 1
All Modes
Enables or disables the Current Monitoring function.
0: Disabled
1: Enabled
All Modes
Sets the current monitoring level as a percentage of the drive's rated current. Sets the level of
current used for L8-89 and H2- = 5C.
Description
All Modes
0: Method 1
1: Method 2
Description
V/f
OLV
Sets the internal speed feedback detection control gain in the automatic frequency regulator
(AFR).
If hunting occurs, increase the set value. If response is low, decrease the set value.
V/f
OLV
Sets the time constant used for speed feedback detection control (AFR).
V/f
OLV
Sets the AFR time constant to be used during regen.
Description
V/f
OLV
0: Disabled
1: Enabled
V/f
OLV
Sets the time required to accelerate the motor at 100% torque from 0 to the nominal speed.
V/f
OLV
Sets the ratio between motor and load inertia. Lower this setting if overshoot occurs at the end
of acceleration.
V/f
OLV
0: Disabled
1: Enabled
2: Test Mode
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
B.3 Parameter Table
Setting
Page
common_
Default: 0
TMonly
Min: -100
240
Max: 100
common_
Default: 1
TMonly
Min: 0
240
Max: 1
common_
Default: 0
TMonly
Min: 0
241
Max: 1
common_
Default: 10.0%
TMonly
Min: 0.0%
241
Max: 50.0%
Setting
Page
common_
Default: 0
TMonly
Min: 0
242
Max: 1
Setting
Page
common_
TMonly
Default: 1.00
Min: 0.00
242
Max: 10.00
Default: 50 ms
common_
TMonly
Min: 0 ms
242
Max: 2000 ms
Default: 750 ms
common_
TMonly
Min: 0 ms
242
Max: 2000 ms
Setting
Page
common_
Default: 0
TMonly
Min: 0
243
Max: 1
Default:
common_
<4>
TMonly
Min: 0.001 s
243
Max: 10.000 s
common_
Default: 1.00
TMonly
Min: 0.00
244
Max: 100.00
common_
TMonly
Default: 1
Min: 0
245
Max: 2
B
419