5.6 F: Option Settings
F1-51: PGoH Detection Level
Sets the level for detecting PG Hardware Fault (PGoH).
Usually the relation between the sin and cos track is
level set in F1-51, a speed feedback hardware fault is detected. Available when F1-20 = 1.
No.
F1-51
F1-52: Communication Speed of Serial Encoder Selection
Note: Available in drive software PRG: 7016 or later.
Selects the speed for serial communication between a PG-F3 option card and serial encoder.
No.
F1-52
Setting 0: 1M bps / 9600 bps (EnDat 2.2/22 / HIPERFACE)
Setting 1: 500k bps / 19200 bps (EnDat 2.2/22 / HIPERFACE)
Setting 2: 1M bps / 38400 bps (EnDat 2.2/22 / HIPERFACE)
Setting 3: 1M bps / 38400 bps (EnDat 2.2/22 / HIPERFACE)
F1-63: PG-E3 R Track Selection
Enables or disables the R phase when a PG-E3 option card is used.
No.
F1-63
Setting 0: Disabled
The R track is not used. The rotor magnet position is calculated from the C and D track signal only.
Setting 1: Enabled
The R track signals are used to determine the rotor magnet position.
F1-66 to F1-81: Encoder Adjust 1 to 16
Note: Available in drive software PRG: 7017 or later.
Sets encoder offsets 1 to 16 for the PG-E3 option card. These parameters are automatically set by the execution of
Auto-Tuning of PG-E3 encoder characteristics.
No.
F1-66 to F1-81

◆ F3: Digital Input Card Settings

These parameters set up the drive for operation with the option card DI-A3. Refer to the instruction manual packaged
with the option card for specific details on installation, wiring, input signal level selection, and parameter setup.
F3-01: DI-A3 Option Card Input Selection
Determines the type of input for digital option card DI-A3 when o1-03 is set to 0 or 1.
No.
F3-01
198
Parameter Name
PGoH Detection Level
Parameter Name
Communication Speed of Serial Encoder Selection
Parameter Name
PG-E3 R Track Selection
Parameter Name
Encoder Adjust 1 to 16
Parameter Name
DI-A3 Option Card Input Selection
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
2
2
sin
θ + cos
θ = 1
. If the value of the square root falls below the
Setting Range
1 to 100%
Setting Range
0 to 3
Setting Range
0, 1
Setting Range
0 to FFFF
Setting Range
0 to 7
Default
80%
Default
0
Default
0
Default
0
Default
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents