Setup Group Parameters
Table 4.4
lists parameters available by default in the Setup Group.
If a parameter that needs to be edited is not displayed in the Setup Group, access the parameter through the Programming
Mode.
Parameter
A1-02
Control Method Selection
b1-01
Speed Reference Selection
C1-01
Acceleration Ramp 1
C1-02
Deceleration Ramp 1
d1-01
Speed Reference 1
d1-02
Speed Reference 2
d1-03
Speed Reference 3
d1-04
Speed Reference 4
d1-26
Leveling Speed
Note: Parameter availability depends on the control mode set in A1-02; some parameters listed above may not be accessible in all
control modes.

◆ Switching Between LOCAL and REMOTE

LOCAL mode is when the drive is set to accept the Up/Down command from the digital operator keypad. REMOTE
mode is when the drive is set to accept the Up/Down command from an external device (via the input terminals or serial
communications, etc.).
Switch the operation between LOCAL and REMOTE using the LO/RE key on the digital operator or via a digital input.
This key is disabled with default settings, but can be enabled by setting parameter o2-01 to 1.
Note: 1. After selecting LOCAL, the LO/RE light will remain lit.
2. The drive will not allow the user to switch between LOCAL and REMOTE during run.
Using the LO/RE Key on the Digital Operator
1.
Turn on the power to the drive. The initial display appears.
Press
. The LO/RE light will light up. The drive is now in LOCAL.
2.
To set the drive for REMOTE operation, press
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Table 4.4 Setup Group Parameters
Name
Step
again.
4.3 The Drive and Programming Modes
Parameter
E1-01
Input Voltage Setting
E1-04
Maximum Output Frequency
E1-05
Maximum Voltage
E1-06
Base Frequency
E1-09
Minimum Output Frequency
E1-13
Base Voltage
E2-01
Motor Rated Current
E2-11
Motor Rated Output
L1-01
Motor Overload Protection Selection
Name
Display/Result
- MODE -
DRV
Rdy
Speed Ref(A1/A2)
U1-01= 0.00%
YEA_c
U1-02= 0.00%
RSEQ
U1-03= 0.00A
RREF
ommon
FWD
FWD/REV
DIGITAL OPERATOR JVOP-180
ALM
- MODE -
DRV
Rdy
Speed Ref (OPR)
U1-01= 0.00%
U1-02= 0.00%
LSEQ
YEA_
U1-03= 0.00A
LREF
FWD
com -
F1
F2
LO
ESC
RE
mon
RESET
ENTER
RUN
STOP
4
103