◆ A2: User Parameters

A2-01 to A2-32: User Parameters 1 to 32
The user can select up to 32 parameters and assign them to parameters A2-01 through A2-32 to provide quicker access by
eliminating the need to scroll through multiple menus. The User Parameter list can also save the most recently edited
parameters.
No.
A2-01 to A2-32
Saving User Parameters
To save specific parameters to A2-01 through A2-32, set parameter A1-01 to 2 to allow access to all parameters, then
enter the parameter number to one of the A2- parameters to assign it to the list of User Parameters. Finally, set A1-01
to 1 to restrict access so users can only set and refer to the parameters saved as User Parameters.
A2-33: User Parameter Automatic Selection
Determines whether recently edited parameters are saved to the second half of the User Parameters (A2-17 to A2-32) for
quicker access.
No.
A2-33
Setting 0: Do not save list of recently viewed parameters.
Set A2-33 to 0 to manually select the parameters listed in the User Parameter group.
Setting 1: Save history of recently viewed parameters.
Set A2-33 to 1 to automatically save recently edited parameters to A2-17 through A2-32. A total of 16 parameters are
saved with the most recently edited parameter set to A2-17, the second most recently to A2-18, and so on. Access the
User Parameters using the Setup Mode of the digital operator.
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Parameter Name
User Parameters 1 to 32
Parameter Name
User Parameter Automatic Selection
5.1 A: Initialization
Setting Range
Default
A1-00 to S6-16
Determined by A1-02
Setting Range
Default
0 or 1
1
5
165