E5: Pm Motor Settings - YASKAWA L1000A Technical Manual

200 v class: 1.5 to 110 kw (2 to 150 hp) 400 v class: 1.5 to 315 kw (2 to 500 hp) 600 v class: 1.5 to 160 kw (2 to 250 hp)
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

E4-05: Motor 2 Line-to-Line Resistance
Sets the line-to-line resistance for the motor 2 stator winding. If Auto-Tuning completes successfully, this value is
automatically calculated. Enter this value as line-to-line and not for each motor phase.
Line-to-Line Resistance on page 189
No.
E4-05
E4-06: Motor 2 Leakage Inductance
Sets the voltage drop due to motor leakage inductance as a percentage of rated voltage of motor 2. This value is
automatically set during Auto-Tuning (Rotational Auto-Tuning and Stationary Auto-Tuning 1, 2).
No.
E4-06

◆ E5: PM Motor Settings

These parameters set the motor data of a PM motor.
For PM motors, Auto-Tuning can be performed. If motor data is known, it can also be entered manually.
Note: 1. E5- parameters are visible only when a PM motor control mode is selected (A1-02 = 7).
2. E5- parameters are not reset when the drive is initialized using parameter A1-03.
E5-02: Motor Rated Power
Sets the rated power of the motor. Determined by the value set to T2-04 during the Auto-Tuning process.
No.
E5-02
E5-03: Motor Rated Current
Sets the motor rated current in amps. Automatically set when the value is entered to T2-06 during Auto-Tuning.
No.
E5-03
Note: The display resolution depends on the rated output power of the drive. Models CIMR-LU20008 to 20033, 40005 to
40018, and 50003 to 50013 display values in 0.01 A units, while models CIMR-LU20047 to 20415, 40024 to
40605, and 50017 to 50200 display values in 0.1 A units.
E5-04: Number of Motor Poles
Sets the number of motor poles. This value is set automatically during Auto-Tuning when the setting of T2-08 is entered.
No.
E5-04
<1> When PG-E3 option connected: Max setting = 48
E5-05: Motor Stator Resistance (Single Phase)
Sets the resistance for one motor phase. Do not enter the line-to-line resistance into E5-05 when measuring the resistance
manually.
No.
E5-05
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
to manually enter this parameter setting.
Parameter Name
Motor 2 Line-to-Line Resistance
Parameter Name
Motor 2 Leakage Inductance
Parameter Name
Motor Rated Power
Parameter Name
Motor Rated Current
Parameter Name
Number of Motor Poles
Parameter Name
Motor Stator Resistance (Single Phase)
5.5 E: Motor Parameters
Refer to E2-05: Motor
Setting Range
0.000 to 65.000 Ω
Setting Range
0.0 to 40.0%
Setting Range
0.10 to 650.00 kW
Setting Range
10 to 200% of drive rated current
Setting Range
2 to 120
<1>
Setting Range
0.000 to 65.000 Ω
Default
Determined by o2-04
Default
Determined by o2-04
Default
Determined by o2-04
Default
Determined by o2-04
5
Default
12
Default
Determined by o2-04
193