24X 2.5-Inch Hdd / Ssd Sas Backplane Cabling - Fujitsu PRIMERGY TX300 S8 Upgrade And Maintenance Manual

Table of Contents

Advertisement

Hard disk drives / solid state drives
7.2.5.3

24x 2.5-inch HDD / SSD SAS backplane cabling

I
Before connecting SAS cables to the controller, bend the cables as
needed in order to reduce strain on the controller. Bend the SAS cables
as close to their shrink tubes as possible.
SAS cabling with SAS expander board and two SAS 2.0 controllers
Cable
(T26139-)
SAS 2.0 cable
Y3963-V151/V101
SAS 2.0 cable
Y3963-V151/V101
SAS 2.0 cable
Y3963-V112
SAS 2.0 cable
Y3963-V112
SAS 2.0 cable
Y3963-V151/V101
SAS 2.0 cable
Y3963-V151/V101
SAS 2.0 cable
Y3963-V107
SAS 2.0 cable
Y3963-V107
200
Cabling
from
list no.
Connector MLC 1 on
16
SAS 2.0 controller 1
in PCI slot 10
Connector MLC 2 on
16
SAS 2.0 controller 1
in PCI slot 10
Connector X3 on
15
SAS expander board
Connector X4 on
15
SAS expander board
Connector X5 on
16
SAS expander board
Connector X6 on
16
SAS expander board
Connector MLC 1 on
18
SAS 2.0 controller 2
in PCI slot 3
Connector MLC 2 on
18
SAS 2.0 controller 2
in PCI slot 3
Upgrade and Maintenance Manual
to
SAS 2.0 backplane 1
connector X1
SAS 2.0 backplane 2
connector X1
SAS 2.0 backplane 3
connector X1
SAS 2.0 backplane 4
connector X1
SAS 2.0 backplane 5
connector X1
SAS 2.0 backplane 6
connector X1
Connector MLC 1 on
SAS expander board
Connector MLC 2 on
SAS expander board
TX300 S8 / RX350 S8
Cabling
plan
16.2.18
16.2.18
16.2.18
16.2.18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primergy rx350 s8

Table of Contents