Fujitsu PRIMERGY TX300 S8 Upgrade And Maintenance Manual page 517

Table of Contents

Advertisement

"Connecting the server to the mains" on page 118
Ê
I
When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the error
message CPU has been changed. This only indicates that the CPU
configuration has been altered. There is no technical problem.
In order to turn off the Global Error indicator, please proceed as
follows:
Ê Restart the system and wait for screen output to appear.
Ê Press the [F2] function key to enter the BIOS.
If assigned, enter the BIOS password and press [Enter].
Ê In the Save & Exit menu, select Save Changes and Exit or Save
Changes and Reset.
Ê Ensure that the Global Error indicator has stopped flashing.
Ê If available, update the system board BIOS and the iRMC to the latest
version as described in section
BIOS and iRMC" on page
"Resetting the error status after replacing memory modules or processors"
Ê
on page 142
"Enabling SVOM boot watchdog functionality" on page 146
Ê
"Enabling replaced components in the system BIOS" on page 147
Ê
Ê If BitLocker functionality is used and has been disabled before starting the
maintenance task:
TX300 S8 / RX350 S8
"Updating or recovering the system board
134.
"Resuming BitLocker functionality" on page 152
Upgrade and Maintenance Manual
Processors
517