9.6.5.2

Removing the FBU holder from the chassis

Figure 349: Removing the FBU holder from the chassis
Ê Carefully disconnect the FBU cable from the RAID controller.
Ê Remove the FBU cable from the cable guide.
Ê Lift up the locking handle on the FBU holder (1, see close-up) while sliding
the FBU holder towards the server front as far as it will go (2).
I
After that, the fixation bolts on the chassis floor will rest in the wide
ends of the keyhole slots on the holder.
Ê Lift the FBU holder out of the chassis.
9.6.5.3
Concluding steps
"Installing the system fan holder" on page 331
Ê
"Installing the system air duct" on page 83
Ê
"Installing the SAS expander board" on page 309
Ê
"Closing the server" on page 98
Ê
Ê When working on a rack-mounted server:
"Mounting the server in the rack" on page 115
"Connecting the server to the mains" on page 118
Ê
TX300 S8 / RX350 S8
Upgrade and Maintenance Manual
Expansion cards and backup units
(if applicable)
455

Hide quick links: