4.1.2.1

Global Error indicator

Figure 4: Global Error indicator on front panel
Ê Check the Global Error indicator on the front or connector panel of the
server:
Indicator
Global error
indicator
Ê For further diagnostics, proceed as follows:
– Hardware errors:
Check the System Event Log (SEL) as described in section
SEL" on page
– Software / agent related errors:
Check the ServerView System Monitor, available on Windows or Linux
based servers with ServerView agents installed.
I
For further information, please refer to the "ServerView System
Monitor" user guide.
TX300 S8 / RX350 S8
Status
Description
off
no critical event (non CSS component)
prefailure detected (non CSS component),
orange on
requires (precautionary) service
intervention
non CSS component failure or software /
orange
agent related error, requires service
flashing
intervention