Concluding Steps; Removing 2.5-Inch Hdd / Ssd Modules; Preliminary Steps - Fujitsu PRIMERGY TX300 S8 Upgrade And Maintenance Manual

Table of Contents

Advertisement

Hard disk drives / solid state drives
7.2.6.4

Concluding steps

Ê When working on a tower server, close the HDD bay cover as described in
section
"Installing accessible drive and HDD bay covers" on page
Ê Please observe the notes on RAID rebuild in section
array rebuild" on page
7.2.7

Removing 2.5-inch HDD / SSD modules

Customer Replaceable Unit
(CRU)
Tools: tool-less
7.2.7.1

Preliminary steps

Ê If the HDD / SSD module to be removed is combined into a RAID array,
please proceed as follows:
RAID level
RAID 0
RAID 1
RAID 5
210
153.
Procedure
Only remove an HDD module combined in a RAID 0
array if defective.
V
CAUTION!
Removing an operational HDD module will
result in data loss!
Removing an HDD module from a RAID 1 or RAID 5
array will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I
After replacing the HDD module, RAID rebuild
will be performed as a background process as
described in section
rebuild" on page
Upgrade and Maintenance Manual
"Performing a RAID
Average task duration:
5 minutes
"Performing a RAID array
153.
TX300 S8 / RX350 S8