Removing A 2.5-Inch Hdd / Ssd Module - Fujitsu PRIMERGY TX300 S8 Upgrade And Maintenance Manual

Table of Contents

Advertisement

In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
V
CAUTION!
All data on all HDDs / SSDs in the array will be lost! Be sure to back
up your data before deleting a RAID array.
For further information, please refer to the "ServerView Suite RAID
Management" user guide.
Ê When working on a tower server, open the HDD bay cover as described in
section
"Removing accessible drive and HDD bay covers" on page
7.2.7.2

Removing a 2.5-inch HDD / SSD module

Figure 112: Disconnecting a 2.5-inch HDD / SSD module
Ê Pinch the green locking clips (1) and fully open the locking lever (2).
I
Thereby, the HDD / SSD module is pushed out of its drive bay by
about 1 cm and disconnected from the SAS / SATA backplane.
TX300 S8 / RX350 S8
Upgrade and Maintenance Manual
Hard disk drives / solid state drives
77.
211

Hide quick links: