7. Open the right maintenance cover.
When opening the cover, make sure
to hold the cover with a holding bar.
Otherwise the cover may fall down
and it may cause some injuries.
8. Clean the suction nozzle using the exclu-
sive cleaning swab moistened with the
washing liquid.
• Carefully clean the suction nozzle.
• Replace the suctions nozzle that is
severely contaminated or bent. Con-
tact your nearest sales agency or
MIMAKI sales office.
• Contact your nearest sales agency or
MIMAKI sales office to order additional
cleaning swab.
9. Wipe off the adherent ink which got on the
cap rubber or inside the suction nozzle
cover with the exclusive cleaning swab.
10. Close the right maintenance cover and then
touch the [ENTER].
The initial operation is performed, then the printer
returns to the LOCAL mode.