Replacing Or Removing Memory Dimms; Figure 18: Memory Dimm Installation - Kontron CG2300 Installation And Maintenance Manual

Carrier grade server
Hide thumbs Also See for CG2300:
Table of Contents

Advertisement

»
Use a ground strap attached to the front panel (with the bezel removed).
To install DIMMs in the S2600CW2SK server board slots, follow these steps:
Open the levers on the DIMM slot. Figure 18, (A)
1.
Note the location of the alignment notch on the DIMM edge. ("B")
2.
Insert the DIMM, making sure the connector edge of the DIMM aligns correctly with the slot. ("E")
3.
Using both hands, push down firmly and evenly on both sides of the DIMM until it snaps into place and the levers close.
4.
("C" and "D")
IMPORTANT: Visually check that each latch is fully closed and correctly engaged with the notch on the DIMM edge. ("E")
Re-install the processor air duct, the right riser card assembly, and the chassis cover. For instructions, see (RJ), (RK),
5.
and (RL) in Chapter 6.
If this is the last task you are doing, plug in the power cord(s) and re-connect any peripheral devices.
6.
5.2.3

Replacing or Removing Memory DIMMs

Before you can replace or remove memory DIMMs in the server, you first need to remove the chassis cover, the right-side riser
card, and the processor air duct. For instructions, see (A), (B1), and (C) in Chapter 4.
40

Figure 18: Memory DIMM Installation

Installation and Maintenance Guide
www.kontron.com