Sign In
Upload
Manuals
Brands
Kontron Manuals
Server
NSC2U
Kontron NSC2U Manuals
Manuals and User Guides for Kontron NSC2U. We have
2
Kontron NSC2U manuals available for free PDF download: Product Manual, Configuration Manual
Kontron NSC2U Product Manual (152 pages)
Brand:
Kontron
| Category:
Server
| Size: 9.07 MB
Table of Contents
Table of Contents
3
Revision History
7
1 Introduction
9
About this Manual
9
Manual Organization
9
What Your Server Includes
9
Product Accessories
10
Additional Information and Software
10
2 Features
12
Server Components
14
NSC2U Server Back Panel
15
NSC2U Server Front Panel
15
NSC2U Server Rear Panel Ethernet Ports
17
SAS Front Panel (SFP) Board
18
SFP Board Features
18
Server Board Connector and Component Locations
19
Hard Disk Drives
20
Riser Card Assembly
20
Full-Height PCI-X/Pcie Riser Card
21
Low-Profile Pcie Riser Card
21
Power Supply
21
System Cooling
21
CPU 1 and Memory Cooling Area
22
CPU 2 and Chipset Cooling Area
22
PCI Cooling Area
22
Hard Disk Drive and Power Supply Cooling
23
Fan Speed Control
23
Cooling Summary
23
Hardware Requirements
24
Processor
24
Memory
24
3 Server Component Installations and Upgrades
25
Before You Begin
25
Tools and Supplies Needed
25
System References
25
General Installation Procedures
25
Removing the Chassis Cover
25
Installing the Chassis Cover
26
Removing the Front Bezel
26
Installing the Front Bezel
27
Removing the Processor Air Duct
27
Installing the Processor Air Duct
28
Hot-Swappable Component Installation Procedures
28
Installing or Replacing a Hard Drive
28
Removing a Hard Drive Tray from the Chassis
29
Attaching a Hard Drive to the Drive Tray
29
Replacing a Power Supply
31
Removing the Power Supply Module
31
Installing the Power Supply Module
32
Grounding a DC-Powered System
32
Internal System Component Configuration and Installation Procedures
32
Configuring Jumpers on the Server Board
32
Configuration Jumpers
33
BIOS Select Jumper
33
DCD/DSR Signal Select Jumper
34
Configuring Memory Dimms
35
Memory RASUM Features
36
Supported Memory
36
DIMM Population Rules and Supported DIMM Configurations
37
Non-Mirrored Mode Minimum Configuration
38
Non-Mirrored Mode Memory Upgrades
39
Mirrored Mode Memory Configuration
40
DIMM Sparing Mode Memory Configuration
40
Single Branch Mode Sparing
40
Dual Branch Mode Sparing
41
Installing Dimms
41
Removing Memory Dimms
42
Adding or Replacing a Processor
43
ESD and Processor Handling Precautions
43
Removing a Processor
44
Installing a New Processor
45
Inserting the Heat Sink
47
Other Installation and Upgrade Options
48
Installing the Server into a Rack
48
Connecting the Power Cord
48
Equipment Rack Precautions
48
4 Optional Component Installations
50
Before You Begin
50
Tools and Supplies Needed
50
System References
50
Cable Routing Reference
50
Installing or Replacing a PCI Add-In Card
51
Riser Card Options
52
Removing the PCI Riser Card Assembly
53
Removing an Add-In Card from the Riser Card Assembly
53
Installing an Add-In Card in the Riser Card Assembly
54
Replacing the Riser Card Assembly on the Server Board
55
Installing an I/O Expansion Module
55
Installing Intel® Remote Management Modules
57
Installing the GCM Module
57
Installing the RMM Module
57
Installing an RJ45 4Xgbe LAN Card for Front Panel Access
58
Installing the LAN Card into the Riser Card Assembly
58
Configuring the RJ45 Gbe LAN Card
59
Routing the LAN Card Cables to the Front Panel
61
Connecting the Gbe LAN Cables to the Front Panel
63
Installing a Fiber LAN Card for Front Panel Access
66
Preparing the Chassis and Removing the PCI Card Carrier Assembly
66
Prepare the Fiber LAN Card and Install It into the Chassis
74
Install the Front Panel Escutcheon and Connect the Fiber Cables
80
Re-Assemble the System
85
Installing a SMART Embedded USB Solid-State Drive
91
Installing Hardware RAID 5 Components
92
Installing the RAID Key and RAID DIMM
93
Installing the RAID Intelligent Battery Backup Unit (IBBU)
93
Installing an Optical Device
95
Removing the Optical Device Filler Panel from the Chassis
95
Installing a New Optical Device
96
5 Server Component Replacements
98
Before You Begin
98
Tools and Supplies Needed
98
System References
98
Cable Routing Reference
98
Replacing the Fan Assemblies
99
Removing the CPU Fans
100
Replacing the CPU Fans
101
Removing the PCI Fan Assembly
102
Replacing the PCI Fans in the Fan Shroud
105
Installing the Fan Assembly Back into the Chassis
106
Replacing the SAS Front Panel Board
107
Removing the LED Light Pipe Assembly
109
Installing the Front Panel Board Back into the Chassis
109
Replacing the Removable Drive Bay Assembly and the SAS Backplane Board
110
Removing the Drive Bay Assembly
111
Removing the SAS Backplane Board from the Drive Bay Assembly
112
Installing a New SAS Backplane Board
112
Installing the Drive Bay Assembly
113
Replacing the Power Distribution Board
114
Removing the Power Distribution Board
114
Installing the Power Distribution Board Back into the Chassis
115
Replacing the Server Board
116
Removing the Server Board
117
Installing the Server Board Back into the Chassis
118
Replacing the Backup Battery on the Server Board
120
6 Server Utilities
122
Using the BIOS Setup Utility
122
Starting Setup
122
If You Cannot Access Setup
122
Setup Menus
122
Upgrading the BIOS
123
Preparing for the Upgrade
124
Recording the Current BIOS Settings
124
Obtaining the Upgrade
124
Updating the BIOS
124
Clearing the CMOS
124
Clearing the Password
125
BMC Force Update Procedure
125
7 Troubleshooting
126
Resetting the System
126
Problems Following Initial System Installation
126
First Steps Checklist
126
Hardware Diagnostic Testing
127
Verifying Proper Operation of Key System Lights
127
Confirming the Operating System Load
128
Specific Problems and Corrective Actions
128
Power Light Does Not Light
128
No Characters Appear on Screen
128
Characters Are Distorted or Incorrect
129
System Cooling Fans Do Not Rotate Properly
129
Cannot Connect to a Server
129
Diagnostics Pass but the Connection Fails
129
The Controller Stopped Working When an Add-In Adapter was Installed
130
The Add-In Adapter Stopped Working Without Apparent Cause
130
System Boots When Installing a PCI Card
130
Problems with Newly Installed Application Software
130
Problems with Application Software that Ran Correctly Earlier
130
Devices Are Not Recognized under Device Manager (Windows* OS)
131
Hard Drive(S) Are Not Recognized
131
LED Information
131
BIOS Error Messages
132
BIOS POST Beep Codes
133
8 Warranty
135
Safety Information
137
Emissions Disclaimer
137
Intended Uses
137
If AC Power Supplies Are Installed
137
A.1 Emissions Disclaimer
137
If DC Power Supplies Are Installed
138
Temperature and Ventilation
139
Safety Cautions
139
Wichtige Sicherheitshinweise
140
Instrucciones de Seguridad Importantes
144
Regulatory and Certification Information
147
Product Regulatory Compliance
147
Product Safety Compliance
147
Product EMC Compliance - Class a Compliance
147
Certifications / Registrations / Declarations
147
Electromagnetic Compatibility Notices
148
Fcc (Usa)
148
Industry Canada (ICES-003)
149
Europe (CE Declaration of Conformity)
149
VCCI (Japan)
149
BSMI (Taiwan)
149
Regulated Specified Components
150
Getting Help
151
World Wide Web
151
Telephone
151
Email
151
Kontron IP Network Server NSC2U Product Guide, Rev. 1.4 December
152
Advertisement
Kontron NSC2U Configuration Manual (21 pages)
IP Network Server
Brand:
Kontron
| Category:
Server
| Size: 1.57 MB
Table of Contents
Revision History
2
Product Description
4
Purpose of this Document
4
I. Introduction
4
II. Ordering Nsc2U System Skus
5
III. Ordering Nsc2U Spares/Accessories
10
IV. Quad Port Bypass Nic Capability
13
Appendix A. Rack Mounting Options for 1U and 2U Communications Rack Mount Servers
15
Advertisement
Related Products
Kontron NSW1U
Kontron NSN2U
Kontron nanoETXexpress
Kontron nanoETXexpress-SP
Kontron nanoETXexpress-HMI Baseboard
Kontron CC2800
Kontron CG1200
Kontron CG2100
Kontron CG2200
Kontron CG2300
Kontron Categories
Computer Hardware
Motherboard
Server
Desktop
PCI Card
More Kontron Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL