Re-Installing The Right Riser Card Assembly; Figure 61: Re-Installing The Left Riser Card Assembly - Kontron CG2300 Installation And Maintenance Manual

Carrier grade server
Hide thumbs Also See for CG2300:
Table of Contents

Advertisement

: 1) To avoid damaging the card edge, be sure that the card is lined up straight with the header, not on an angle.
NOTES
2) If a hardware RAID controller card is installed in PCI slot 3, be careful not to damage the diagnostic pins at the
back of the card next to the rear chassis panel when re-installing the left-side riser assembly.
3. Align and then tighten the blue captive retention screws at the front of the assembly with the holes on the support cross
bar ("C") and on the rear of the chassis. ("D".
4. Replace the chassis cover. For instructions see (RL) here in Chapter 6.
6.12.2

Re-Installing the Right Riser Card Assembly

To re-install the riser card assembly:
1.
Position the riser front tabs over the holes on the PCI support cross bar (over the processor air duct). (Figure 62).
2.
Using the blue touch points on the top of the assembly ("A"), press down to mate the riser card with the header on the
server board ("B", slot 6 for the right-side riser)
88

Figure 61: Re-Installing the Left Riser Card Assembly

Installation and Maintenance Guide
www.kontron.com