Kontron CG2300 Installation And Maintenance Manual page 106

Carrier grade server
Hide thumbs Also See for CG2300:
Table of Contents

Advertisement

Color
State
Green
Solid on
Green
Blink
Amber
Blink
Amber
Solid on
Off
N/A
106
Table 5: System Status LED Definitions
Criticality
System OK
System booted and ready
System degraded:
Degraded
Non-fatal alarm – system is likely to fail:
Non-critical
Fatal alarm – system has failed or shut down
Critical, non-
recoverable
(NOTE: This state also occurs when power is first applied to the
system. This indicates the BMC is booting)
Power off, if no degraded, non-critical, critical, or non-
recoverable conditions exist.
Not ready
Installation and Maintenance Guide
Description
Non-critical temperature threshold asserted
Non-critical voltage threshold asserted
 Non-critical fan threshold asserted
 Fan redundancy lost, sufficient system cooling
maintained. This does not apply to non-redundant
systems.
 Power supply predictive failure
 Power supply redundancy lost. This does not apply
to non-redundant systems.
Corrective errors over a threshold of 10 and migrating
to a mirrored DIMM (memory mirroring). This indicates
the user no longer has spare DIMMs indicating a
redundancy lost condition. The corresponding DIMM
LED should light up
Critical temperature threshold asserted
 CATERR asserted
 Critical voltage threshold asserted
 VRD not asserted
 SMI timeout asserted
CPU missing
Thermal Trip asserted
 Non-recoverable temperature threshold asserted
 Non-recoverable voltage threshold asserted
 Power fault/power control failure
 Fan redundancy lost, insufficient system cooling.
This does not apply to non-redundant systems.
 Power supply redundancy lost, insufficient system
power. This does not apply to non-redundant
systems.
www.kontron.com