Hide thumbs Also See for CG2300:
Table of Contents

Advertisement

3. Holding the locking lever on the plastic tray out, slide the module/tray assembly towards the back of the bracket until it
locks into place.
4. Connect the signal/power pigtail cable to the proper connector on the hardware RAID controller board ("C") and the
rear of the battery backup assembly. (Figure 31, "F")
5. Place the battery backup bracket on the support cross bar, lining it up with the center hole on the middle shelf. ("G")
6. Use the blue retention screw to fasten the battery backup assembly bracket to the cross bar.
7. Re-install the left-side riser card assembly and the chassis cover. For instructions, see (RK) and (RL) in Chapter 6.
8. If this is the last task you are performing, plug in the power cord(s) and re-attach any peripheral devices.
5.2.9

Installing a PCIe Riser Card

The CG2300 server does not ship with any PCI riser cards, just the sheet metal brackets where the riser cards and PCI add-in
cards are housed. The S2600CW2SK server board has two riser slots capable of supporting riser cards on the right side and left
side of the chassis. Baseboard PCIe slot 2 (left side) and PCIe slot 6 (right side) support the riser cards in the CG2300 system.
Baseboard PCIe slot 2 supports a single slot PCIe X16 riser or a dual slot PCIe X8 riser. These risers are referred to as the 'left'
risers since the boards plug in on the left side of the chassis as viewed from the front of the server. PCIe riser cards in slot 2
connect to CPU2. Baseboard PCIe slot 6 supports a single slot PCIe X16 riser or a dual slot PCIe X8 riser. These risers are
referred to as the 'right' risers since the boards plug in on the right side of the chassis. PCIe riser cards in slot 2 connect to CPU1.
Table 3 identifies the card configurations and the connector types used.
Once PCIe add-in cards are installed and the riser card assembly is remounted in the chassis, the cards are accessible from the
rear of the server chassis.
Table 3 identifies the card configurations and the connector types used.
52

Figure 32: Setting Up the Battery Backup Assembly

Installation and Maintenance Guide