(10) Adjusting the scanner leading edge registration

Perform the following adjustment if there is regular error between the leading edges of the copy image and original.
U034
U066
(P. 1-6-10)
Caution:
Before making the following adjustment, ensure that the above adjustments have been made in maintenance mode.
Procedure
Enter maintenance mode.
Enter "066" using the numeric keys.
Press the start key.
Select the item to be adjusted.
Press the interrupt key.
Place an original and press
the start key to make a test copy.
Is the scanner
leading edge registration
Press the stop/clear key to
exit maintenance mode.
U071
(P. 1-4-26)
Start
No
correct?
Yes
End
Scanner leading edge registration
Original
ADJUST DATA: Scanner leading
edge registration
ADJUST DATA2: Scanner leading
edge registration for rotate copying
Press the start key.
The new setting
is stored.
For copy example 1, increase
the value using the cursor up key.
For copy example 2, decrease
the value using the cursor down key.
Setting range (initial setting)
ADJUST DATA: -32 - +32 (-5)
ADJUST DATA2: -20 - +20 (10)
Changing the value by 1 moves
the leading edge by 0.17 mm.
2FD/2FF/2FG-3.0
Copy
Copy
example 2
example 1
Figure 1-6-56
1-6-29