Setting The Fixing Control Temperature - Kyocera KM-3035 Service Manual

Hide thumbs Also See for KM-3035:
Table of Contents

Advertisement

2FD/2FF/2FG-3.0
Maintenance
item No.
U161

Setting the fixing control temperature

Description
Changes the fixing control temperature.
Purpose
Normally no change is necessary. However, can be used to prevent curling or creasing of paper, or solve a
fixing problem on thick paper.
Method
1. Press the start key. The screen for selecting an item is displa yed.
2. Select the item to be set and press the star t key. The screen for executing each item is displayed.
Display
CONTROL TEMP
CORRECT TEMP
Setting the fixing control temperature
1. Select the item to be set. The selecting item is displayed in reverse.
2. Change the setting using the cursor up/down keys.
Display
CONT TEMP
1ST TEMP
2ND TEMP
WARM UP TIM (S)
DUP DOWN TEMP1 Fixing temperature decrease amount
DUP DOWN TEMP2 Fixing temperature decrease amount
The respective temperatures are to be set such that 2ND TEMP > = 1ST TEMP .
3. Press the start key. The value is set.
Setting the fixing correct temperature
1. Select the item to be set. The selecting item is displayed in reverse.
2. Change the setting using the cursor up/down keys.
Display
COPY UP TEMP(L)
COPY UP TEMP(M)
COPY UP TEMP(S)
L/L UP TEMP
H/H DOWN TEMP
MH OFF UP TEMP
If the fixing offset occurs by over heat of fixing temperature, decrease the value of MH OFF UP TEMP to
lower the temperature of fixing heater M.
3. Press the start key. The value is set.
Interrupt copy mode
While this maintenance item is being performed, copying from an original can be made in interrupt copy mode.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for selecting a maintenance item No . is
displayed.
1-4-40
Description
Description
Sets the fixing control temperature.
Sets the fixing correct temperature.
Description
Control temperature during copying
Primary stabilization fixing
temperature
Secondary stabilization fixing
temperature
Time from power on to stabilization of fixing -5 to +20
for duplex copying
for duplex copying for copy store
section/optional mail box ejection
Description
Fixing correct temperature
for large size copying
Fixing correct temperature
for middle size copying
Fixing correct temperature
for small size copying
Fixing temperature increase amount
at low temperature and low humidity
Fixing temperature decrease amount
at high temperature and high humidity
Variable range of correct temperature
for fixing heater M
Setting range
Initial setting
100 to 200 (°C) 130
80 to 200 (°C)
115 (30 cpm)
120 (40/50 cpm)
100 to 200 (°C) 130 (30 cpm)
145 (40/50 cpm)
0
0 to +20 (°C)
5
0 to +20 (°C)
0
Setting range
Initial setting
-30 to +100 (°C) 45 (30 cpm)
50 (40 cpm)
65 (50 cpm)
-30 to +100 (°C) 45 (30 cpm)
60 (40 cpm)
70 (50 cpm)
-30 to +100 (°C) 25 (30 cpm)
40 (40 cpm)
45 (50 cpm)
0 to +20 (°C)
5
0 to +20 (°C)
0
-10 to 10
0