12. Remove a screw, turn the metal fittings
upward, and fit the screw again to the lower
hole.
13. Insert the intermediate tray and connect the
connector (white) of the intermediate tray to
the transfer unit. Connect the connectors
(gray) to the connectors of the copier as
shown in the illustration.
Connect the gray connector with more pins to
the upper connector and the gray connector
with less pins to the lower connector.
14. Attach the intermediate tray to the copier as
shown in the illustration so that the right and
left pins of the intermediate tray are
positioned to the recessed portions of the
copier and the transfer unit.
1-3-42
Recessed portion
Transfer unit
Metal fittings
Screw
Screw
Figure 1-3-94
Connector (white)
Intermediate tray
Figure 1-3-95
Figure 1-3-96
Connector (gray)
Pin
Recessed porton
Intermediate tray