(2) Detaching and refitting the bypass separation, bypass paper feed and bypass forwarding pulleys
Follow the procedure below to replace the bypass separation, bypass paper feed and bypass forwarding pulleys.
Procedure

• Removing the bypass unit

1. Remove the four screws holding the lower
right cover and then the cover.
2. Remove the two screws holding the bypass
unit and disconnect the two connectors, and
then remove the unit.

• Removing the bypass separation pulley

3. Reverse the bypass unit and remove the
spring and stop ring from the bypass
separation pulley and move the bushing
inside.
Lower right cover
Figure 1-6-7
Figure 1-6-8
Bushing
Bypass separation shaft
Spring
Figure 1-6-9
2FD/2FF/2FG
Connectors
Bypass unit
Stop ring
1-6-5