Kyocera KM-3035 Service Manual page 221

Hide thumbs Also See for KM-3035:
Table of Contents

Advertisement

Problem
(4)
Defective main PCB.
The eject motor
does not operate.
(5)
Broken upper lift motor
The upper lift motor
coil.
does not operate
Poor contact in the upper
(C1010).
lift motor connector termi-
nals.
Defective main PCB.
(6)
Broken lower lift motor
The lower lift motor
coil.
does not operate
Poor contact in the lower
(C1020).
lift motor connector termi-
nals.
Defective main PCB.
(7)
Broken scanner motor coil.
The scanner motor
does not operate.
Poor contact in the scan-
ner motor connector termi-
nals.
(8)
Broken cooling fan motor 1
Cooling fan motor 1
coil.
does not operate.
Poor contact in the cooling
fan motor 1 connector ter-
minals.
(9)
Broken cooling fan motor 2
Cooling fan motor 2
coil.
does not operate.
Poor contact in the cooling
fan motor 2 connector ter-
minals.
(10)
Broken cooling fan motor 3
Cooling fan motor 3
coil.
does not operate.
Poor contact in the cooling
fan motor 3 connector ter-
minals.
(11)
Broken cooling fan motor 4
Cooling fan motor 4
coil.
does not operate.
Poor contact in the cooling
fan motor 4 connector ter-
minals.
Causes
Run maintenance item U030 and check if YC16-B11, YC16-B12,
YC16-B13 and YC16-B14 on the main PCB go low. If not,
replace the main PCB.
Check for continuity across the coil. If none, replace the upper
lift motor.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Check if 24 V DC is output across YC13-A17 on the main PCB
right after the upper drawer is installed. If not, replace the main
PCB.
Check for continuity across the coil. If none, replace the lower lift
motor.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Check if 24 V DC is output across YC13-B7 on the main PCB
right after the lower drawer is installed. If not, replace the main
PCB.
Check for continuity across the coil. If none, replace the scanner
motor.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Check for continuity across the coil. If none, replace cooling fan
motor 1.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, repair or replace the cable.
Check for continuity across the coil. If none, replace cooling fan
motor 2.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, repair or replace the cable.
Check for continuity across the coil. If none, replace cooling fan
motor 3.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, repair or replace the cable.
Check for continuity across the coil. If none, replace cooling fan
motor 4.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, repair or replace the cable.
Check procedures/corrective measures
2FD/2FF/2FG
1-5-47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-4035Km-5035

Table of Contents