(12) Adjusting the margins for scanning an original on the contact glass

Perform the following adjustment if the margins are not correct.
U402
U403
(P. 1-6-13)
Caution:
Before making the following adjustment, ensure that the above adjustments have been made in maintenance mode.
Procedure
Enter maintenance mode.
Enter "403" using the numeric keys.
Press the start key.
Select the item to be adjusted.
Press the interrupt key.
to make a test copy.
Are the margins correct?
Yes
Proceed to another mode?
Press the stop/clear key to
exit maintenance mode.
U404
(P. 1-4-63)
Start
Press the start key
Yes
No
End
A MARGIN: scanner left margin
B MARGIN: scanner leading edge margin
C MARGIN: scanner right margin
D MARGIN: scanner trailing edge margin
Press the start key.
Change the setting.
Increasing the value using the cursor
No
up key makes the margin wider.
Decreasing the value using the
cursor down key makes the margin
narrower.
Setting range (default)
Scanner left margin: 0 – +10 (3)
Scanner leading edge margin: 0 – +10 (3)
Scanner right margin: 0 – +10 (1.5)
Scanner trailing edge margin: 0 – +10 (1)
Changing the value by one moves
the margin by 0.1 mm for all.
Ejection direction
(reference)
The new setting
is stored.
Scanner leading edge margin
Scanner
left margin
(2 ± 1.0 mm)
Scanner trailing edge margin
(2 ± 1.0 mm)
Figure 1-6-58
2FD/2FF/2FG
(3 ± 1.5 mm)
Scanner
right margin
(2 ± 1.0 mm)
1-6-31