5. Remove the two screws and detach the
connector and then remove the fan duct.
6. Remove the six screws holding the toner
container retainer and then the retainer.
7. Remove the four screws and detach the
connector and then remove the laser scanner
unit.
8. Replace the laser scanner unit and refit all
the removed parts.
Fan duct
Figure 1-6-41
Toner container retainer
Figure 1-6-42
Connector
Laser scanner unit
Figure 1-6-43