Kyocera KM-3035 Service Manual page 314

Hide thumbs Also See for KM-3035:
Table of Contents

Advertisement

2FD/2FF/2FG
Connector Pin No.
YC9
A1
A2
Connected
A3
to the
A4
BYPFSW,
A5
TCS, TNS,
A6
developing
A7
unit,
A8
TNFSOL,
A9
TCDSW
A10
and drum
A11
unit.
A12
A13
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
YC10
A1
A2
Connected
A3
to the RSW,
A4
fixing unit,
A5
DUPFCL,
A6
DUPPCSW
A7
and CFM 5
A8
to 7.
A9
A10
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
YC11
1
3
Connected
5
to the DM,
7
PFM, FCL1
9
and FSW1.
11
13
2
4
6
8
10
12
14
2-3-10
Signal
I/O
GND
-
BYPFSW
I
5V
O
5V
O
TCS
I
GND
-
PO
-
5V
O
TNS
I
GND
-
DVUNITN
I
FUSE CUT REM
O
N.C
-
GND
-
TNFSOL
O
TCDSW
I
GND
-
PO
-
GND
-
CL
O
EEDATA
O
EESCLK
O
GND
-
DRUNITN
I
5V
O
N.C
-
GND
-
RSW
I
5V
O
PO
-
5V
I
FTH1
I
FUSE CUT REM
I
GND
-
5V
I
FTH2
I
24V
O
DUPFCL
O
GND
-
DUPPCSW
I
5V
I
GND
-
SET SIG
I
DUP PO
-
R24V
O
CFM5,6,7
O
R24V
O
PG
-
5V
O
SG
-
DM S/S
O
DM L/D
I
DM CLK
O
R24V
O
PG
-
5V
O
SG
-
PFM S/S
O
PFM L/D
I
FCL1
O
Voltage
-
Ground
0/5 V DC
BYPFSW ON/OFF
5 V DC
5 V DC supply for BYPFSW
5 V DC
5 V DC supply for TCS
0/5 V DC
TCS ON/OFF
-
Ground
-
Ground
5 V DC
5 V DC supply for TNS
0/5 V DC
TNS ON/OFF
-
Ground
0/5 V DC
Developing unit detection signal
0/5 V DC
Developing unit FUSE CUT signal
-
Not used
-
Ground
0/24 V DC
TNFSOL ON/OFF
0/5 V DC
TCDSW ON/OFF
-
Ground
-
Ground
-
Ground
0/5 V DC
CL ON/OFF
0/5 V DC
Drum unit DATA signal
0/5 V DC
Drum unit CLOCK signal
-
Ground
0/5 V DC
Drum unit detection signal
5 V DC
5 V DC supply for drum unit
-
Not used
-
Ground
0/5 V DC
RSW ON/OFF
5 V DC
5 V DC supply for RSW
-
Ground
5 V DC
5 V DC supply from FTH1
0 to 5 V DC
FTH1 detection voltage
0/5 V DC
FTH1 detection voltage
-
Ground
5 V DC
5 V DC supply from FTH2
0 to 5 V DC
FTH2 detection voltage
24 V DC
24 V DC supply for DUPFCL
0/24 V DC
DUPFCL ON/OFF
-
Ground
0/5 V DC
DUPPCSW ON/OFF
5 V DC
5 V DC supply from DUPPCSW
-
Ground
0/5 V DC
Duplex section connection signal
-
Ground
24 V DC
24 V DC supply for CFM5 to 7
0/24 V DC
CFM5 to 7 ON/OFF
24 V DC
24 V DC supply for DM
-
Ground
5 V DC
5 V DC supply for DM
-
Ground
0/24 V DC
DM S/S signal
0/24 V DC
DM L/D signal
0/5 V DC (pulse)
DM CLOCK signal
24 V DC
24 V DC supply for PFM
-
Ground
5 V DC
5 V DC supply for PFM
-
Ground
0/24 V DC
PFM S/S signal
0/24 V DC
PFM L/D signal
0/24 V DC
FCL1 ON/OFF