Kyocera KM-3035 Service Manual page 41

Hide thumbs Also See for KM-3035:
Table of Contents

Advertisement

2FD/2FF/2FG
3. Open the drawer of the paper feeder and loosen the three screws securing the adjuster.
A and B: test pattern output examples
4. If the test pattern output example looks like A, move the adjuster in the direction of the white arrow (e) and retighten
the three screws.
If the test pattern output example looks like B, move the adjuster in the direction of the black arrow (b) and retighten
the three screws.
5. Output the test pattern again.
6. Repeat steps 3 to 5 until the centers of the paper and the test pattern are aligned.
A
*If necessary, please fix the cassette cursor
with the screws included in the machine box.
1-3-16
B
Figure 1-3-27
Drawer
Screws
Adjuster

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-4035Km-5035

Table of Contents